Bulletin 855XH Horn
Electrical Connection
Raccordement Electrique
Elektrischer Anschluß
Collegamento Elettrico
Ligações Eléctricas
Conexiones Eléctricas
If fitting 2 wires to one terminal the sum of the 2 wires must be a maximum cross sectional area of 2.5mm². Wires may also be fitted
using ferrules. When connecting wires to the terminals care should be taken to dress the wires so that when the cover is inserted
into the chamber the wires do not exert excess pressure on the terminal blocks. This is particularly important when using cables with
large cross sectional areas such as 2.5mm².
AC Wiring
Terminal blocks are provided on the AC horns for power connection. There are (2) Line, (2) Neutral and (2) Earth Ground terminals
in total. A 3-position terminal is provided for stage switching with a stage 2, a stage 3 and a common terminal.
(Customer supplied
switches)
8mm
(0.31 in)
20-14AWG (0.5-2.5mm²)
To energize the 3 stage tones on AC units:
Stage one (S1) Operation
Publication 855X-IN001A-EN-E- August 2019
Wiring practices must meet applicable electrical codes.
Les procédures de câblage doivent répondre aux codes électriques en vigueur.
Bei der Verdrahtung sind die geltenden elektrotechnischen Sicherheitsvorschriften zu befolgen.
Le procedure adottate per i cavi devono rispettare le codifiche elettriche applicabili.
A instalação da fiação deve atender aos códigos elétricos aplicáveis.
Las prácticas de instalación eléctrica deben seguir los códigos eléctricos.
AC Simplified Block Diagram
N
L
Stage two (S2) Operation
Simply
connect the
supply
voltage to
the L and N
supply
terminals.
0.45 Nm (4 lb-in)
AC Terminals
Power L and
N.
Link the
Common (C)
and S2
terminals.
Volume
(-8dB)
S3
S2
DIP Switch
(Tone selection)
C
Stage three (S3) Operation
Power L and
N.
Link the
Common (C)
and S3
terminals.