Electrical Connection; Pneumatic Connection; Hydraulic Connection - ATH-Heinl 7226 Manual Del Usuario

Tabla de contenido
2.6

Electrical Connection

General and local regulations must be observed. Therefore, these steps may only be
carried out by a trained professional.
Pay attention to the necessary supply line (see technical data).
The connection should be made with a 230V Schuko plug or 5-phase 16 A CEE plug (partially included).
Voltage deviations should be 0.9 - 1.1 times the nominal voltage range and the frequency deviation should
be 0.99 - 1.01 times the frequency range.
Necessary protective measures must be taken to guarantee this.
At the end of the work, the direction that the motor rotates must be checked.
2.7

Pneumatic Connection

For all pneumatic systems, a compressed air maintenance unit (partially included) must
be installed between the supply line and the system.
The air pressure of the supply line must at least correspond to the technical data.
The compressed air maintenance unit must be set correctly and checked.
The compressed air maintenance unit must be serviced at regular intervals.
The maximum or minimum pressure ensures perfect functioning without any damage.
2.8

Hydraulic Connection

Before the system is put into operation or operated for the first time with oil, the
following must be observed with regard to the optimal, trouble-free and almost air-free
functioning
All hydraulic lines must be connected and tightened according to the hydraulic plan and, if applicable
according to the hose designation.
All hydraulic lines and cylinders must be vented according to the hydraulic plan and, if applicable, according
to the hose designation.
In order to ensure the faultless and safe functioning of the system and the hose assemblies used, the
hydraulic fluids used must comply with the specific instructions and recommendations of the manufacturer.
Used media that do not meet the specific requirements or which have unauthorised contamination damage
the entire hydraulic system and shorten the service life of the hydraulic systems used. Warning: (system
contamination can also occur when oil is refilled)
The minimum requirement and minimum oil quantity must be checked and ensured.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03