ACM MATIX Serie Instrucciones Y Advertencias Para El Instalador página 15

Tabla de contenido
FIG.6
SX: Left Installation
DX: Right Installation
ADJUSTMENT OF THE MATIX M Ø45-Ø55 LIMIT SWITCH
Figure 7 illustrates that whatever the type of installation (right or left), screw "A" regulates the downward movement
and screw "B" the upward movement. Bring the rolling shutter (or awning) down by pressing the button. If the rolling
shutter does not descend far enough, turn screw "A" anticlockwise (clockwise for left installation) and with the button
pressed bring it down to the position required. If, instead, the rolling shutter stops beyond the position required move
it back using the control buttons and then turn screw "A" in a clockwise direction (anticlockwise for left installation) to
reduce the travelling distance so that the rolling shutter remains stationary even if the button is pressed down. At this
point repeat the foregoing operations for the maximum opening of the rolling shutter. Press the button to wind up
the rolling shutter. If the rolling shutter stops lower than required down turn screw "B" anticlockwise (clockwise for left
installation) until it reaches the position required. If the rolling shutter stops beyond the position required turn screw
"B" clockwise (anticlockwise for left installation) to reduce the travelling distance.
FIG.7
Double regolation
SX: Left Installation
DX: Right Installation