Manuale del d'uso ed installazione – M360M 2000
(GB) INSTALLATION
The table must be set properly, adjusting if necessary the height of the feet (M). It is not necessary to fix the
machine to the floor.
ELECTRICAL CONNECTION
The table has no general switch. Therefore it must be connected to a socket with 16 A minimum intensity,
fitted with a switch and a magnetothermic differentials of at least 3 mm.
NOTE: The control panel socket (G) must not be used for connections of any kind.
OPERATION TO FOLLOW FOR THE WORKING OF THE MACHINE
1) Connect the general switch on the feeding line (A).
2) Put the adjusting thermostat (B) on position "5" (about in the middle of the regulation dial). In this way
the temperature of the working board is about 80°C.
3) Await a few minutes until when the temperature of the working board is reached.
4) Press the pedal (E). The motor of suction will start working. (The motor remains connected until when the
pedal (E) is pressed).
ATTENTIONS
1) The maintenance has to be carried out exclusively by specialized staff.
2) Replace periodically the cover cloth of the table to enable a correct suction.
3) The working table has never to be left when the iron is feeded and leant on the cover cloth; in any case the
suction table and the iron have to be switched off and the iron placed on its support.
OPERATION TO EXECUTE AT THE END OF THE WORK
1)
Disconnect the general switch (A).
HOW TO ASSEMBLE THE LAMP HOLDER ARM
1) Mount the two arm supports (D) on to the base using the supplied bolts.
2) Insert the lamp into tube (H) and the accessories into tube (F).
3) Fit the tubes (F) and (H) into the arm supports (C) without tightening the adjuster knobs.
4) Insert the two arm supports (C) into supports (D) previously fixed to the base (at least two persons are required
for this operation).
5) Fix the arm supports (C) to the table using the relative bolts (Q).
6) Tighten the adjuster knobs of supports (D) and arm supports (C).
HOW TO ASSEMBLE THE CLOTH SIDE PANELS
1) Remove the cloth tube (S) from one of its connections and insert the cloth (P) on to it.
2) Fit the tubes (S) back into their supports and tighten the adjuster knobs.
3) The supports (L) allow for an adjustment margin of about 20 cm. Their position can be adapted by means of the
adjuster knobs (R).
Del 03-01-2007 - C:\SETTORE STIRO\M360M2000\MANUALE ISTRUZIONI\M360M 2000.doc
Pag. 8 di 16