We recommended vacuum
–
packing and sealing only one bag
per minute to allow the appliance
to recover sufficiently.
If for any reason the necessary
–
vacuum is not obtained, the
vacuum system will automatically
disconnect after 45 seconds. In this
case, check whether the bag has a
leak or is not properly positioned.
ONCE YOU HAVE FINISHED USING
THE APPLIANCE
Unplug the appliance from
–
the mains.
Put the cable back in the
–
cable housing.
Clean the appliance.
–
Cleaning
Disconnect the appliance from the
–
mains and allow it to cool before
undertaking any cleaning task.
Clean the equipment with a damp
–
cloth with a few drops of washing-
up liquid and then dry.
Do not use solvents, or products
–
with an acid or base pH such as
bleach, or abrasive products, for
cleaning the appliance.
Never submerge the appliance in
–
water or any other liquid or place it
under running water.
CLEANING THE VACUUM CHAMBER
Open the cover of the vacuum
–
packing machine by pressing the
two side buttons.
With a cloth or damped sponge
–
and soap.
TROUBLESHOOTING
IF NOTHING HAPPENS ON
PRESSURISING THE PACKING
MACHINE
Make sure the electrical cord is
–
properly plugged into the mains.
Check the cord and the mains
–
socket and make sure these are
not damaged in any way.
If you find any damage do not use
–
the packing machine.
THE AIR HAS NOT BEEN
COMPLETELY EXPELLED FROM
THE BAG
For correct packing the end of
–
the bag must remain inside the
vacuum chamber.
Check for possible dirt on the
–
sealing band or in the vacuum
chamber. If there is any dirt, clean
them and reposition them in their
locations.
The bag may be punctured. To
–
check this, seal the bag with a little
air inside, submerge it in water and
apply pressure. If bubbles form,
this means that there is a leak. Use
another bag.
Check that the cover is
–
completely closed.
THE BAGS OF THE PACKING
MACHINE LOSE VACUUM
AFTER SEALING
Creases, crumbs, grease or liquids
–
may be released from the sealed
EN