Safety Measures; Application Areas; Technical Data; Scope Of Delivery - T.I.P. BPF 8000 E Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Check the device for transport damage. If there is damage the retailer must be notified without delay, at the latest
however, within 8 days of the purchase date.

2. Safety measures

Attention! Use in garden ponds and the protected area of garden ponds is only permitted if the installation complies
with the valid regulations. Consult a qualified electrician.
Attention! Do not use the pump in or on swimming pools!
Prior to use:
Check the mains cable and plug for damage.
Mains voltage and current type must agree with the information on the type plate.
Only connect the pump via a residual current circuit breaker (RCCB, ∆ = 30 mA) to a proper earthing contact
socket.
Install the connection socket in the water-protected area and at least 2 m away from the edge of the pond.
Always protect the mains plug from moisture.
Unplug the mains plug before performing any work on the pump, fountain or pond.
Do not operate the pump if there are people in the water (disconnect the pump from the mains supply beforehand!)
Important! If there is damage to the mains cables or the motor housing the complete pump is unusable and must
be disposed of. Repair is not possible because the connecting cable is permanently cast in the motor housing.
Never suspend or transport the pump by the mains cable.
This pump is equipped with a permanent magnet, whose magnetic fields could influence pacemakers, interfere
with electrical/electronic components and wipe data carriers.
People with pacemakers should always maintain a safety distance of at least 30 cm from the pump.

3. Application areas

This product is an immersion pump, the motor is completely cast in epoxy resin. The pumps are designed for use in
water, such as: garden pond, fish pond, fountains, for operating filter systems, streams, etc. as well as for water aeration
and circulation. This device has been developed for private use and not for industrial or commercial purposes.
The pump is not suitable for displacement of salt water, faecal matter, flammable, corrosive or other hazardous liquids.
The pumped liquid must not exceed the maximum temperature specified in the technical data.

4. Technical data

Model
Mains voltage / frequency
Rated power
Degree of protection
Max. flow rate (Q
) *
max
Max. pressure
Max. delivery head (H
) *
max
Max. immersion depth
Maximum temperature of the pumped liquid (T
Length of line cord
Type of cord
Net weight
Item Part Nr.
* The values were determined with free, unreduced outlet

5. Scope of delivery

Pump with 10 m cable, 2 hose connection ports (∅ 25 mm / ∅ 32 and 40mm), operating instructions.
)
max
2
BPF 8000 E
220 - 240 V~ 50 Hz
70 Watt
IPX8
8000 l/h
0,45 bar
4,5 m
2 m
6 mm
35 °C
10 m
H05RN-F
4,1 kg
7
Tabla de contenido
loading

Tabla de contenido