<RBC-AMT32E>
1
3
4
6
1
5
2
1
Push and hold
button and "TEMP."
button simultaneously for at least 4
seconds. After a while, the display flashes
as shown in the figure. Confirm that the
CODE No. is [01].
• If the CODE No. is not [01], push
clear the display content, and repeat the
procedure from the beginning. (No operation of
the remote controller is accepted for a while
after
button is pushed.)
(While hot water modules are operated under
the group control, "ALL" is displayed first. When
is pushed, the indoor unit number
displayed following "ALL" is the header unit.)
(* Display content varies with the indoor unit (including hot
water module) model.)
123-EN
2
Each time
button is pushed, hot
water module numbers in the control group
change cyclically. Select the hot water
module to change settings for.
The LED on the P.C. board of the selected hot
water module flashes. The hot water module for
change settings can be confirmed.
Hot Water Module P.C. board
LED
Flashing
button to
3
Specify CODE No. [
] with "TEMP."
buttons.
4
Select SET DATA [
] with "TIME"
buttons.
5
Push
button. When the display changes
from flashing to lit, the setup is completed.
• To change settings of another hot water module,
2
repeat from Procedure
.
• To change other settings of the selected hot
water module, repeat from Procedure
Use
button to clear the settings. To make
settings after
button was pushed, repeat from
2
Procedure
.
6
When settings have been completed, push
button to determine the settings.
When
button is pushed,
then the display content disappears and the hot
water module enters the normal stop mode.
(While
is flashing, no operation of the
remote controller is accepted.)
<RBC-AMS55E-ES/EN>
Field setting menu(1/2)
1.Test mode
2.Register service info.
3.Alarm history
4.Monitor function
5.Setting louver position
Return
Item
/
1. Test mode
2. Register service info
/
3. Alarm history
4. Monitor function
5. Setting louver position
6. Setting timer operation mode
7. DN setting
3
.
8. Reset power consumption data
flashes and
– 62 –
1
Push the [
menu screen.
2
Push and hold the [
∨
the [
] button at the same time to
display the "Field setting menu".
Set
Push and hold the buttons for more than 4
seconds.
3
Push the [
Function
Settings for when performing the test operation after installation
Registration of information about the contact number for service, model name and
serial number of the indoor unit and outdoor unit
List of latest 10 alarm data: information of check code, date, time, and unit
Monitoring data of sensor temperature, rotating speed of the compressor or other
factor.
Change the louver indication setting to match the indoor unit type.
Set whether or not the operation mode can be selected when setting the schedule
timer.
Advanced settings using DN code
Resetting the power consumption data saved in the remote controller.
MENU ] button to display the
MENU ] button and
CANCEL ] button to return.