Nota:
* Peak / Track: Track mode: Current torque value - Peak mode: Maximum torque value
*1: The accuracy of the readout is guaranteed from 20% to 100% of maximum range + /- 1
increment. The torque accuracy is a typical value. Calibration line is at the middle line of the
dark spot on the rubber handle. For keeping the accuracy, calibrate the wrench for a constant
period time (1 year). And the accuracy is based on the zero degree of offset from perpendicu-
lar drive.
*2: Use a special designed cable (accessory) to upload record data to PC.
*3: Horizontal and vertical test.
*4: Environmental test:
a. Dry heat
b. Cold
c. Damp heat
d. Change of temperature
e. Impact (shock)
f. Vibration
g. Drop
*5: Electromagnetic compatibility test:
a. Electrostatic discharge immunity (ESD)
b. Radiated susceptibility
c. Radiated emission
22
.