The indicator is on, but
the compressor does
not work and buzzes
only
The compressor stops
a minute after starting,
and restarts after a few
minutes repeatedly.
The compressor works
normally, but the
temperature inside the
cabinet goes down too
slowly.
The noise is too loud
The following are not failures:
△ When the freezer is working or after is stops for a while, the refrigerant in the
pipes is cycling and produces "running water" sounds.
△ The surface temperature of the compressor may be up 70℃~80℃ when it is
working.
△ The back side of the freezer gives out heat.
△ In rainy season, the outer surface of the cabinet may have dew, which is not
a defect on normal use. Just dry it with a piece of cloth.
The power voltage is<
98V.
The power voltage is>
132V.
The door is opened too
frequently.
There is too much food
inside the cabinet
And/ or it is improperly
placed.
The frost film is too thick.
The surface of the
condenser is too dirty.
The door is not sealing.
The freezer not level.
The freezer door is
loose.
There is contact
between the back pipes
and the exterior walls.
2
Install a
power-regulator over
1000W.
Reduce door opening
times.
Place foods properly
keeping space
between them for
ventilation of cold air.
Take out the food and
defrost the freezer.
Stop and clean the
condenser.
Adjust the door seal.
Level the freezer.
Tighten the door.
Separate the pipes
from the exterior walls.