item #1000000000
Model #90600120
Use and Care GUide
MOTiOn sensOr MOdULe
FCC ID: XZH-9050102016
THANK YOU
We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this motion
sensor module. We strive to continually create quality products designed to enhance your home. Visit us online to see
our full line of products available for your home improvement needs. Thank you for choosing Commercial Electric!
Warranty
WHAT IS COVERED
The manufacturer warrants this product to be free from defects in materials and workmanship for
a period of five (5) years from date of purchase. This warranty applies only to the original consumer
purchaser and only to products used in normal use and service. If this product is found to be defective,
the manufacturer's only obligation, and your exclusive remedy, is the repair or replacement of the
product at the manufacturer's discretion, provided that the product has not been damaged through
misuse, abuse, accident, modifications, alterations, neglect, or mishandling.
WHAT IS NOT COVERED
This warranty shall not apply to any product that is found to have been improperly installed, set-up, or
used in any way not in accordance with the instructions supplied with the product. This warranty shall
not apply to a failure of the product as a result of an accident, misuse, abuse, negligence, alteration,
faulty installation, or any other failure not relating to faulty material or workmanship. This warranty
shall not apply to the finish on any portion of the product, such as surface and/or weathering, as this is
considered normal wear and tear.
The manufacturer does not warrant and specifically disclaims any warranty, whether express or
implied, of fitness for a particular purpose, other than the warranty contained herein. The manufacturer
specifically disclaims any liability and shall not be liable for any consequential or incidental loss or
damage, including but not limited to any labor / expense costs involved in the replacement or repair of
said product.
Contact the Customer Service Team at 1-877-527-0313 or visit www.HomeDepot.com.
Questions, problems, missing parts? Before returning to the store,
call Commercial Electric Customer Service
8 a.m. - 7 p.m., EST, Monday - Friday, 9 a.m. - 6 p.m., EST, Saturday
1-877-527-0313
HOmEDEpOT.COm
safety information
WarninG: Carefully read and understand the
FCC ID:XZH-90600120
information given in this manual before beginning the
nOTiCe: This device complies with Part 15 of the FCC
assembly and installation. Failure to do so could lead
Rules. Operation is subject to the following two conditions:
to electric shock, fire, or other injuries which could be
(1) This device may not cause harmful interference, and (2)
hazardous or even fatal.
this device must accept any interference received, including
interference that may cause undesired operation.
CaUTiOn: Changes / modifications not approved by the
WarninG: Ensure the electricity to the wires you
are working on is shut off. Either remove the fuse or
responsible party could void the user's authority to operate
turn off the circuit breaker.
the equipment.
Care and Cleaning
CaUTiOn: Before attempting to clean the sensor, disconnect the power to the fixture by turning the breaker
off or removing the fuse from the fuse box.
Clean the sensor with a soft, dry cloth.
Do not use cleaners with chemicals, solvents, or harsh abrasives.
Do not use liquid cleaner on the sensor.
Pre-installation
Before beginning assembly, installation or operation of the product, make sure all parts are present.
Compare parts with the package contents list. If any part is missing or damaged, do not attempt to
assemble, install or operate the product. Contact customer service for replacement parts.
nOTe: Keep your receipt and these instructions for proof of purchase.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do
the installation.
TOOlS REqUIRED
Wire Strippers
Safety Goggles
Ladder
Gloves
pACKAgE CONTENTS
part
Description
quantity
A
A
Motion Sensor Module
1
HARDWARE INClUDED
part
Description
quantity
AA
Locknut (3/4 in.)
1
BB
Lock Washer (3/4 in.)
1
CC
Locknut (1/2 in.)
1
AA
BB
CC
DD
EE
DD
Lock Washer (1/2 in.)
1
EE
Wire Connectors
3
FF
Male to Male Connector
1
installation
WarninG: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off.
Either remove the fuse or turn off the circuit breaker before beginning assembly or installation.
nOTiCe: This motion sensor module works with direct hard wired LED and fluorescent light fixtures as well as
with selected Commercial Electric linkable plug-in LED light fixtures. Visit HomeDepot.com for a list of compatible
Commercial Electric linkable plug-in fixtures.
nOTiCe: The motion sensor can be used for fixtures installed up to 18 feet high.
installing for Use with direct Wired Fixtures
1
preparing the fixture
Remove the diffuser/lens to allow access to the
fixture wiring.
Remove the knockout
Knockout holes
where you wish to mount
the sensor module.
installing for Use with direct Wired Fixtures (continued)
2
3
Determining the knockout size
Feeding the wires
Choose the appropriate knockout size for
Feed the electrical connection wires from
your fixture, either 3/4" or 1/2", and use only
the sensor module (A) through the selected
the locknut and lock washer for that size.
knockout hole and then through the lock
washer (BB/DD) followed by the locknut
(AA/CC).
A
A
A
4
Connecting the sensor module to the fixture
Insert the threaded end of the sensor module (A) completely
into the selected knockout hole and through the lock washer
(BB/DD). Then tighten the locknut (AA/CC) securely onto the
threaded end of the sensor module (A).
nOTe: For a firm fit, gently use pliers to tighten the locknut (AA/CC).
5
making the electrical connections
Connect the hot (black) wire from the sensor (A) to the black
wire from the electrical box.
Connect the neutral (white) wire from the sensor (A) to the
Pliers
white wire from the fixture and the white wire from the
electrical box.
Connect the secondary live wire
(red) from the sensor (A) to the live
wire (black) from the fixture.
Cover the three wire connections
using the wire connectors (EE).
nOTiCe: The green wire from the fixture
should continue to be connected to the
grounding wire from the electrical box.
A
6
Attaching the diffuser to the housing
FF
Replace the diffuser/lens on the light fixture.
Restore power to the electrical box.
Turn on the light switch to activate the
fixture.
installing for use with selected Commercial electric linkable
plug-in Led light fixtures
1
2
Connecting the sensor module to the
preparing the fixture
fixture
Unplug the power cord from the
Insert the small male-to-male connector (FF) to
electrical outlet and from the light
the Power Out side of the sensor module (A).
fixture.
Push the other end of the male-to-male
connector (FF) into the Power end of the fixture.
Make sure both connections fit securely.
nOTe: The sensor module (A) notes which end is
Power In and which is Power Out.
FF
A
installing for use with selected Commercial electric linkable
plug-in Led light fixtures (continued)
3
Turning on the power
Insert the power cord firmly into the Power In end of
the sensor module (A).
Plug the power cord into the electrical outlet.
Turn on the light fixture.
nOTe: The lock washer (BB or DD) and
locknut (AA or CC) should be on the inside of
adjusting the Motion sensor
the fixture wall with the wires coming through
the center of each.
The sensor comes from the factory with the following settings:
Detection Area: 75%
BB/DD
Hold Time: 5 Minutes
AA/CC
Daylight Sensor: Photocell Disabled
Motion Sensor
Hold-time
Detection Area
DIP 1
DIP 2
DIP 3
DIP 4
n
n
75%
5 minutes
To adjust the settings, simply move the DIp switches to the settings you prefer.
BB/DD
Detection area
The motion detection
area can be adjusted
by selecting the
I
combination of settings
II
on the DIP switches
AA/CC
III
for the desired motion
detection area.
IV
Hold-time
Hold-time is the time period the light will remain
on after the person has left the detected area.
The amount of time the light remains on can be
adjusted by selecting the combination of settings
Black
on the DIP switches for the desired hold-time.
Daylight sensor
BB/DD
White
The daylight threshold can be adjusted by
selecting the combination of settings on the DIP
switches to determine the level of darkness when
the light will turn on automatically.
Troubleshooting
Black
AA/CC
EE
Red
WarninG: Before doing any work on the motion sensor module, disconnect power to the light fixture.
Minor problems often can be fixed without the help of an electrician.
Problem
Possible Cause
The fixture will not light.
The power is off.
There is a bad connection. Check to ensure proper wire connections are made. Contact a qualified electrician.
The motion sensor module
is mounted higher than
18 ft.
The fuse blows or the
The wires are crossed
circuit breaker trips when
or the power wire is
the light is turned on.
grounding out.
The light is not staying on
The hold-time setting
long enough after the last
needs to be adjusted.
motion is detected.
The light is staying on too
The hold-time setting
long after the last motion is
needs to be adjusted.
detected.
The motion sensor is not
The motion sensor needs
detecting motion in a large
to be adjusted.
enough area.
The motion sensor is
The motion sensor needs
detecting motion in too
to be adjusted.
large an area.
The motion sensor is
The daylight sensor needs
A
detecting motion during
to be adjusted.
daylight hours and turning
the light on when I do not
need it on.
The motion sensor is not
The daylight sensor needs
detecting motion and
to be adjusted.
turning the light on during
daylight hours when I
need it to.
FF
A
Daylight Sensor
Light Level
DIP 5
DIP 6
n
n
Disabled
DIP Switches
I - 100%
detection area
Coverage By install Height
II - 75%
III - 50%
DIP 1
DIP 2
10 ft. Ceiling
9 ft. Ceiling
8 ft. Ceiling
IV - 10%
100%
43 ft. x 10 ft.
40 ft. x 9 ft.
39 ft. x 8 ft.
n
n
75%
36 ft. x 10 ft.
34 ft. x 9 ft.
33 ft. x 8 ft.
n
50%
26 ft. x 10 ft.
23 ft. x 9 ft.
23 ft. x 8 ft.
n
10%
7 ft. x 10 ft.
7 ft. x 9 ft.
7 ft. x 8 ft.
I - 5 sec.
DIP 3
DIP 4
II - 90 sec.
I
5 sec.
n
n
III - 5 min.
II
IV - 15 min.
90 sec.
n
III
n
5 min.
IV
15 min.
I - Disable
DIP 5
DIP 6
II - 50 lux.
I
Disable
n
n
III - 10 lux.
II
IV - 2 lux.
50 lux.
n
III
10 lux.
n
IV
2 lux.
solution
Ensure the power supply and circuit breaker are both in the on position.
Mount the fixture with the motion sensor module at 18 ft. or lower.
Check the wire connections.
Contact a qualified electrician or call Commercial Electric customer service
1-877-527-0313.
Factory setting is a 5 minute hold time. To increase the time
period the light remains on, please refer to the Adjusting the
IV
15 min.
Motion Sensor section of the instruction manual to adjust the
4th dip switch to the preferred setting.
Factory setting is a 5 minute hold time. To decrease the time
period the light remains on, please refer to the Adjusting the
I
5 sec.
n
n
Motion Sensor section of the instruction manual to adjust the
II
n
90 sec.
3rd and 4th dip switches to the preferred setting.
To increase the motion detection area, please refer to the
Adjusting the Motion Sensor section of the instruction manual
I
n
n
100%
to adjust the 1st and 2nd dip switches to the preferred setting.
To decrease the motion detection area, please refer to the
III
Adjusting the Motion Sensor section of the instruction manual
50%
n
to adjust the 1st and 2nd dip switches to the preferred setting.
IV
10%
Ensure the 5th and 6th dip switches are set to detect light at
II
the 50 lux, 10 lux or 2 lux settings. Please refer to the Adjusting
n
50 lux.
the Motion Sensor section of the instruction manual to adjust
III
n
10 lux.
the 5th and 6th dip switches to the preferred setting.
IV
2 lux.
Ensure the 5th and 6th dip switches are set at "disable". This
will allow the light to turn on when motion is detected at any
light level. Please refer to the Adjusting the Motion Sensor
I
n
n
Disable
section of the instruction manual to adjust the 5th and 6th dip
switches to the preferred setting.