5. Trouble Shooting
Use the table below to solve minor problems.
Problem
Possible Cause
LED display on the
Low battery
front panel does not
Battery fault
work.
The UPS is not turned on.
Alarm continuously
The UPS is overload.
sounds when the
mains is normal.
When power fails,
The UPS is overload.
back-up time is
shorten.
Battery voltage is too low.
Battery defect. It might be
due to high temperature
operation environment, or
improper operation to battery.
The mains is normal
Power cord is loose.
Bu the unit is on
battery mode.
6 Specifications
Model
FP 1000
CAPACITY
1000 VA / 600 W
INPUT
Voltage
Voltage Range
OUTPUT
Voltage Regulation
Transfer Time
Waveform
BATTERY
Type & Number
12 V/7 AH x 2
Charging Time
PHYSICAL
Dimension (DxWxH)
Net Weight (kgs)
8.2
Environment
0-90 % RH @ 0-40° C (non-condensing)
Humidity
Noise Level
Solutions
Charge the UPS at least 6 hours.
Replace the battery with the same
type of battery.
Press the power switch again to turn
on the UPS.
Remove some loads first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
Remove some critical load. Entfernen
Sie nicht notwendige
Spannungsgeräte.
Charge the UPS at least 6 hours.
Replace the battery with the same
type of battery.
Reconnect the power cord properly.
FP 1500
FP 2000
1500 VA / 900 W
2000 VA / 1200 W
220/230/240 VAC
162-290 VAC
+/-10%
Typical 2-6 ms, 10 ms max.
Simulated Sine Wave
12 V/9 AH x 2
12 V/9 AH x 2
4-6 hours recover to 90% capacity
320 x 130 x 182 mm
10.4
11.0
Less than 40 dB
4
Line Interactive UPS
1. Lieferumfang
Im Lieferumfang sollten Sie folgendes finden:
- USV Einheit
- Kurzanleitung
- Netzkabel (nur für Modelle mit IEC-Eingang)
2. Produktü bersicht
Vorderansicht:
Rü ckansicht:
FP 1000
FP 1500/2000
Quick Guide V.1.1
Ein/Aus Schalter
Betriebsanzeige: grün
Batteriemodus: gelb blinkend
Fehlermeldung: rot
Ausgänge
AC Eingang
Schutzschalte
USB port
Modem / Telefon /
Netzwerk
Ü berspannungsschutz
5
DE