SYSTEM LOGIC
Depending on the application, different probe types must be used. The following tables are provided as a guideline for
selecting the appropiate probe type:
•
Fresh fluid tank (alarms are generated as fluid level
decreases):
•
Waste fluid tank (alarms are generated as fluid level
increases):
NOTE: See page 9 for "Setting the input type" . Also, most
commong float-type probes can be converted from N.O. to
N.C. and vice versa by just flipping the float.
SYSTEM INTERFACE
STATUS INDICATORS
The unit has six LED indicators on the front cover. When
the unit is in standby mode (the switch key is in "normal"
position), the white "POWER" LED will be lit. If any of the
four probe inputs is triggered, the associated "CH" red
8
SB 3050 R. 06/20
Balcrank Corporation - Weaverville - NC · Tel.: 800-747-5300 · www.balcrank.com
Configured
Float type
as N.O.
N.O.
N.C.
Configured as
Float type
N.O.
N.C.
LED will blink. Also, if the bypass key is switched from
"normal" position to "bypass" position, the yellow
"BYPASS" LED will be lit, indicating that the unit is in
"bypass" mode.
Configured
as N.C.
No
Yes
Yes
No
Configured as
N.O.
N.C.
Yes
No
No
Yes