Mount to Wall (solid concrete or concrete block)
Mark the locations for the lag bolts on the
1
corners of a rectangle measuring 406.4 (16 in.)
wide and 578.4 mm (231⁄8 in.) for the CFR1615
and 809.6 mm (317⁄8 in.) for the CFR1620 tall.
4 0 6 .6 m m
(1 6 in .)
C F R 1 6 1 5
5 7 8 .4 m m
(2 3 1⁄8 in .)
C F R 1 6 2 0
8 0 9 .6 m m
(3 1 7⁄8 in .)
10
2
Drill pilot holes as illustrated.
CAUTION:
To avoid potential injuries or
property damage:
 Pilot holes MUST be drilled to a depth of 89 mm
(3½ in.) using a 10 mm (3/8 in.) diameter drill bit.
 Never drill into the mortar between blocks.
 Minimum solid concrete thickness: 8 in.
 Minimum concrete block size: 8 x 8 x 16 in.
10 mm
(3/8 in.)
89 mm
(3½ in.)