AVRX550U
AVRX750U
UPS System
Not suitable for mobile applications.
Important Safety Instructions
SAVE THESE INSTRUCTIONS— This manual con-
tains instructions and warnings that should be followed
during the installation, operation and storage of all
Tripp Lite UPS Systems. Failure to heed these warnings
will void your warranty.
UPS Location Warnings
• Install UPS indoors, away from excess moisture or
heat, conductive contaminants, dust or direct sunlight.
• Keep the indoor temperature between 32º F and 104º
F (0º C and 40º C).
• Leave adequate space around all sides of UPS for
proper ventilation.
UPS Connection Warnings
• Connect UPS directly to a properly grounded AC
power outlet. Do not plug UPS into itself; this will
damage the UPS.
• Do not modify the UPS's plug, and do not use an adapter
that would eliminate the UPS's ground connection.
• Do not use extension cords to connect UPS to an AC
outlet. Warranty will be voided if anything other than
Tripp Lite surge suppressors are used to connect UPS
to an outlet.
• If UPS receives power from a motor-powered AC
generator, the generator must provide clean, filtered,
computer-grade output.
• The main socket outlet that supplies the UPS should be
installed near the UPS and should be easily accessible.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life support
applications in which a malfunction or failure of a
Tripp Lite UPS System could cause failure or signifi-
cantly alter the performance of a life-support device.
• Do not connect surge suppressors or extension cords
to the output of UPS. This might damage the UPS and
will void the surge suppressor and UPS warranties.
Battery Warnings
• Batteries can present a risk of electrical shock and
burn from high short-circuit current. Observe proper
precautions. Do not dispose of the batteries in a fire.
Do not open the UPS or batteries. Do not short or
bridge the battery terminals with any object. Unplug
and turn off the UPS before performing battery
replacement. Use tools with insulated handles. There
are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized
service personnel using the same number and type of
batteries (sealed Lead-Acid). The batteries are recy-
clable. Refer to your local codes for disposal require-
ments or in the USA only call 1-800-SAV-LEAD or
1-800-8-BATTERY (1-800-822-8837)
www.rbrc.com for recycling information. Tripp Lite
offers a complete line of UPS System Replacement
Battery Cartridges (R.B.C.).Visit Tripp Lite on the
Web at www.tripplite.com to locate the specific
replacement battery for your UPS.
Storage and Service
Storage
To avoid battery drain, all connected equipment should
be turned off and disconnected from the UPS. Press and
hold the ON/OFF/TEST switch for one second. Your
UPS will be completely turned off (deactivated), and
will be ready for storage. If you plan on storing your
UPS for an extended period, fully recharge the UPS
batteries every three months. Plug the UPS into a live
AC outlet, turn it on by pressing and holding the
ON/OFF/TEST switch for one second, and allow the
batteries to recharge for 4 to 6 hours. If you leave your
UPS batteries discharged for a long period of time, they
will suffer a permanent loss of capacity.
Service
Before returning your UPS for service, follow these steps:
Note: Save your original packaging in case your UPS needs to
be shipped for service.
1. Review the installation and operation instructions in
this manual to ensure that the service problem does
not originate from a misreading of the instructions.
2. If the problem continues, do not contact or return the
UPS to the dealer. Instead, call Tripp Lite at (773) 869-
1234 domestically or (773) 869-1212 internationally. A
service technician will ask for the UPS's model num-
ber, serial number and purchase date and will attempt
to correct the problem over the phone.
3. If the problem requires service, the technician will issue
you a Returned Material Authorization (RMA) num-
ber, which is required for service. Securely pack the
UPS in its original packaging to avoid damage during
shipping. Do not use Styrofoam beads for packaging.
If you require packaging, the technician can arrange
to send you proper packaging. Any damages (direct,
indirect, special, incidental or consequential) to the
UPS incurred during shipment to Tripp Lite or an
authorized Tripp Lite service center is not covered
under warranty. UPS Systems shipped to Tripp Lite
or an authorized Tripp Lite service center must have
transportation charges prepaid. Mark the RMA num-
ber on the outside of the package. If the UPS System
is within the 2-year warranty period, enclose a copy
of your sales receipt. Return the UPS for service
using an insured carrier to the address given to you
by the Tripp Lite service technician.
Manuel de l'utilisateur
Onduleur
AVRX550U
AVRX750U
Non approprié aux applications mobiles.
Mesures de sécurité
importantes
CONSERVEZ CES INSTRUCTIONS— Ce manuel
contient les instructions et avertissements à respecter
pour l'installation, l'utilisation et l'entreposage de tous
les onduleurs Tripp Lite. Le non-respect de ces aver-
tissements annulerait votre garantie.
Avertissements concernant le lieu
d'installation de l'onduleur
• Installez l'onduleur dans un local à l'abri d'une
humidité et d'une température excessives, de
saletés conductrices d'électricité, de la poussière et de
la lumière du soleil.
• Maintenez la température du local entre 0º C à 40º C
(32º F et 104º F).
• Maintenez un espace suffisant autour de l'onduleur
pour assurer sa bonne ventilation.
Avertissement concernant le
raccordement de l'onduleur
• Raccordez l'onduleur directement à une prise
d'alimentation CA avec terre. Ne raccordez pas
le câble d'alimentation de l'onduleur dans sa
propre prise car cela l'endommagerait.
• Ne modifiez pas la fiche de l'onduleur et n'utilisez
aucun adaptateur qui supprimerait sa mise à la terre.
• N'utilisez pas de rallonge pour raccorder l'onduleur à
une prise d'alimentation. La garantie serait annulée si
vous raccordez l'onduleur à une prise d'alimentation
par tout intermédiaire autre qu'un parasurtenseur
Tripp Lite.
• Si l'onduleur est alimenté par un générateur CA à
moteur, ce générateur doit fournir une sortie propre et
filtrée de qualité prévue pour l'alimentation
d'ordinateurs.
• La prise d'alimentation principale qui alimente l'ond-
uleur devrait être installée à sa proximité et facile-
ment accessible.
Avertissements concernant la connexion
des appareils
• N'utilisez pas les onduleurs Tripp Lite pour l'alimen-
tation d'équipements médicaux de soutien vital car un
mauvais fonctionnement ou une panne de l'onduleur
pourrait provoquer une panne ou une baisse de per-
formance de tels équipements.
• Ne connectez pas de parasurtenseur ni de rallonge
électrique à la sortie de l'onduleur. Cela pourrait
endommager l'onduleur et annulerait la garantie du
parasurtenseur ainsi que celle de l'onduleur.
Avertissements concernant les batteries
• Parce que les batteries présentent un risque de choc
électrique et de courant de court-circuit élevé, prenez
les précautions nécessaires. Ne pas jeter les batteries
au feu. Ne pas ouvrir les batteries. Ne pas établir de
court-circuit ou de pont entre les bornes de la batterie
avec un quelqconque objet. Débrancher et éteindre
l'UPS avant de remplacer la batterie. Le remplace-
ment de la batterie doit être confié à du personnel de
service qualifié. Utiliser des outils ayant des poignées
isolées et remplacer les batteries existantes par des
batteries neuves du même numéro et du même type
(batterie sans entretien). Les batteries UPS sont recy-
clables. Consultez les codes locaux concernant les
exigences d'élimination des déchets, ou au E.-
U.seulement, consultez ces sources pour des ren-
seignements concernant le recyclage : 1-800-SAV-
LEAD
(1-800-728-5323);
1-800-8-BATTERY
(1-800-8-228-8379); www.rbrc.com. Tripp Lite offre
une gamme complète de cartouches de batterie de
remplacement de système UPS (R.B.C.). Rendez visite
à Tripp Lite sur le Web à www.tripplite.com pour trouver
la batterie de remplacement spécifique à votre UPS.
Entreposage et entretien
Entreposage
Tous les équipements connectés doivent être arrêtés
puis débranchés de l'UPS pour éviter de vider la bat-
terie. Débrancher d'abord l'UPS de la prise murale, puis
appuyer et maintenir le bouton ON/OFF/TEST pendant
une seconde. L'UPS sera alors à l'arrêt complet (désac-
tivé).Votre UPS est maintenant prêt pour l'entreposage.
Si vous envisagez d'entreposer votre UPS pour une
longue période, recharger complètement les batteries
une fois tous les trois mois en branchant l'UPS dans une
prise c.a. alimentée et en le laissant en charge pendant
4 à 6 heures. Si vous laissez vos batteries UPS
déchargées pendant une longue période, elles souf-
friront d'une perte permanente de capacité.
Entretien
Avant d'envoyer votre onduleur en réparation, suivez
ces étapes :
Remarque : Conservez l'emballage d'origine en cas de besoin
pour envoi en réparation.
1. Relisez les instructions d'installation et le mode
d'emploi de ce manuel pour vous assurer que le prob-
lème ne provient pas d'une erreur de lecture des
instructions.
2. Si le problème persiste, ne vous adressez pas au dis-
tributeur et ne lui renvoyez pas l'onduleur. Appelez
directement Tripp Lite au (773) 869-1234 (USA) ou
au +1 (773) 869-1212 (international). Le technicien
du service après-vente vous demandera le numéro de
modèle de votre onduleur, son numéro de série et la
date d'achat, et tentera de remédier au problème par
téléphone.
3. Si le problème nécessite une réparation, le technicien
vous donnera un numéro d'autorisation de retour de
matériel
(N°
RMA
:
"Returned
Authorization"), obligatoire pour faire effectuer la
réparation. Emballez soigneusement l'onduleur dans
son conditionnement d'origine pour éviter qu'il soit
endommagé durant l'expédition. N'utilisez pas de
billes de mousse pour l'emballage. Si vous avez
besoin d'un emballage, le technicien peut vous faire
envoyer l'emballage approprié. Tout dommage
(direct, indirect, particulier, accessoire ou consécu-
tif) subi par l'onduleur pendant l'expédition à Tripp
Lite ou à un centre de réparation agréé par Tripp Lite
n'est pas couvert par la garantie. Le port des ond-
uleurs expédiés à Tripp Lite ou à un centre de répa-
ration agréé de Tripp Lite doit être prépayé. Indiquez
le numéro d'autorisation de retour de matériel
(RMA) sur l'extérieur de l'emballage. Si l'onduleur
est encore sous garantie (2 ans à partir de la date
d'achat), joignez une copie de votre preuve d'achat.
Renvoyez l'onduleur pour réparation par l'intermédi-
aire d'un service de messagerie assuré à l'adresse qui
vous aura été donnée par le technicien de Tripp Lite.
Installation
1
STEP 1: Unplug the computer's power cord from both your AC outlet and the com-
puter's AC input. Insert the female plug of the computer's cord (B) into your UPS's
AC input. Insert the male plug of your computer's cord into your AC outlet that does
not share a circuit with a heavy electrical load. Insert the female plug of the power
cord that came with your UPS (A) into the computer's AC input. Insert the UPS
cord's male plug into any of your UPS's battery backup female output receptacles.
STEP 2: Plug remaining equipment into the UPS.
STEP 3: Push the ON/OFF/TEST button for one second to turn the UPS on (see
Controls Section). Please Note! The UPS will not turn on automatically in the pres-
ence of live utility power.
Controls
A
ON/OFF/TEST Button
• To turn the UPS on: Press and hold the ON/OFF/TEST Button for one sec-
ond.* If utility power is absent, pressing the button will "cold-start" the UPS,
i.e. turn it on and supply power from its batteries.**
• To turn the UPS off: Press and hold the ON/OFF/TEST switch for one sec-
ond.* The UPS will be turned completely off (deactivated).
• To run a Self-Test: With your UPS plugged in and turned ON, press and hold
the ON/OFF/TEST button for three seconds.
CAUTION! To perform a self-test, you must hold the ON/OFF/TEST button
continuously for three seconds. If you release the button too early, you will turn
the UPS system OFF and cut power to connected equipment loads. To ensure you
hold the button for the correct length of time, do not release the button until you
hear the UPS System's audible alarm beep twice. The first beep occurs after one
second and indicates that the UPS will turn OFF if the button is released. The sec-
ond beep occurs after three seconds and indicates that the UPS will perform a self-
test if the button is released.
The test will last approximately 10 seconds as the UPS switches to battery to
test its load capacity and charge. All LEDs will be lit and the UPS alarm will
sound. See LED descriptions below to determine the results of the Self-Test.
Note: You can leave connected equipment on during a self-test.
CAUTION! Do not unplug your UPS to test its batteries. This will remove safe
electrical grounding and may introduce a damaging surge into your network
connections.
*The alarm will beep once briefly after one second has passed. **If fully charged
B
"ON/OFF" LED: this green LED lights continuously to indicate that the UPS is
ON and supplying your equipment with AC power either from a utility source or
from the UPS's internal batteries. If the UPS's alarm is sounding (4 short beeps
followed by a pause), the UPS is operating from its internal batteries.
or
visit
C
"OVERLOAD/CHECK BATTERY" LED: this red LED lights continuously
after a self-test to indicate the capacity of the outlets has been exceeded. To clear
the overload, unplug some of your equipment from the outlets; then use the
ON/OFF/TEST button to run a Self-Test. If the UPS continues to detect an over-
load, remove more equipment and repeat the self test until successful. CAU-
TION! Any overload that is not corrected by the user immediately following a
self-test may cause the UPS to shut down and cease supplying output power in
the event of a blackout or brownout. The LED flashes to indicate the battery
needs to be recharged or replaced. If the LED flashes (and a continuous alarm
sounds) during a prolonged blackout or brownout, the UPS's batteries are nearly
out of power; you should save files and shut down your equipment immediately.
If the LED flashes following a UPS self-test (after the UPS is turned ON), it may
indicate that the battery needs to be replaced. Allow the UPS to recharge contin-
uously for 12 hours; then use the ON/OFF/TEST button to run a Self Test. If the
LED continues to flash, contact Tripp Lite for service. Should your UPS require
battery replacement, visit Tripp Lite on the Web at www.tripplite.com to locate
the specific replacement battery for your UPS.
D
Automatic Voltage Regulation (internal, not shown): Automatically adjusts
fluctuations to incoming voltage (under/over voltages) to supply connected
equipment with 230V computer-grade output power. Automatic voltage regula-
tion functions separately from battery power (will not drain battery).
E
Battery Backup Protected/Surge Protected Outlets: Provide both battery
backup and surge protection. Plug your computer, monitor and other critical
equipment into these outlets. NOTE: DO NOT PLUG LASER PRINTERS
INTO THESE OUTLETS.
Surge Protected-only outlets.
E2
F
AC Input Outlet: accepts a user-supplied power cord with a country-specific plug.
G
USB Communication Port: This port can connect your UPS to any computer for
automatic file saves and unattended shutdown in the event of a power failure. Use
with Tripp Lite's PowerAlert Software and appropriate USB cable. A PowerAlert
CD and USB cable may be included with your UPS; if so, insert the CD into the
CD tray of your computer and follow the installation instructions. If PowerAlert
Software and the appropriate cable did not come with your UPS, you can obtain
the software FREE via the Web at www.tripplite.com. Any USB cable may then
be used to connect your UPS to your computer. NOTE: This connection is option-
al. The UPS will work properly without this connection.
CAUTION: Users shall take proper care to minimize Electro-Static events.
In the event of a severe Electro-Static Discharge on or near the USB port,
this UPS may shut down automatically. In the case of a shut down, the UPS
will need to be turned back on.
Tel/DSL Protection Jacks: Stop surges on the phone or fax line. INTER-
H
NETX750AVR models feature a built-in splitter (one jack in/two jacks out),
allowing you to connect two devices sharing a single line. Connecting your
equipment to these jacks is optional. Your UPS will work properly without this
connection.
Battery Replacement Door (bottom panel, not shown): Under normal condi-
I
tions, the original battery in your UPS will last several years. Battery replacement
should be performed only by qualified service personnel. Refer to "Battery
Warnings" in the Safety section. Should your UPS require battery replacement,
visit Tripp Lite on the Web at www.tripplite.com to locate the specific replace-
ment battery for your UPS.
G
Warranty
2-YEAR LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and
workmanship for a period of 2 years (except batteries outside USA and Canada, 1 year) from the date of initial purchase. If the
product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole
discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or
delivery charges prepaid) to: Tripp Lite; 1111 W. 35th Street; Chicago, IL 60609; USA. Seller will pay return shipping charges. Call
Tripp Lite Customer Service at (773) 869-1234 before sending any equipment back for repair.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT,
MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET
FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING
ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET
FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES.
(Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or lim-
itation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives
you specific legal rights, and you may have other rights, which vary from jurisdiction to jurisdiction).
Tripp Lite; 1111 W. 35th Street; Chicago, IL 60609; USA
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for
the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or war-
ranty as to the suitability or fitness of these devices for any specific application.
Policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique
series number. The series number can be found on the product nameplate label, along with all required approval markings and
information. When requesting compliance information for this product, always refer to the series number. The series number
should not be confused with the marking name or model number of the product.
This product designed and engineered in the USA.
Material
Note on Labeling
Two symbols are used on the label.
V~ : AC Voltage
V
: DC Voltage
Remarque sur l'étiquetage
Deux symboles sont utilisés sur
l'étiquette :
V~ : Tension CA
V
: Tension CC
Installation
2
ETAPE 1 : Déconnectez le cordon d'alimentation de votre ordinateur de la prise d'al-
imentation et de sa prise d'entrée CA. Insérez la fiche femelle du cordon de l'ordina-
teur (B) dans la prise d'entrée CA de l'onduleur. Insérez la fiche mâle du cordon de
l'ordinateur dans une prise d'alimentation qui ne partage pas de circuit supportant une
forte charge. Insérez la fiche femelle du cordon d'alimentation livré avec votre ond-
uleur (A) dans la prise d'entrée CA de l'ordinateur. Insérez la fiche mâle du cordon d'al-
imentation de l'onduleur dans un de ses réceptacles femelles de sortie.
ETAPE 2 : Connectez l'équipement restant à l'onduleur.
ETAPE 3 : Après avoir branché le UPS dans une prise murale, appuyez sur le bou-
ton ON/OFF/TEST (marche/arrêt/test) pendant une seconde pour mettre en marche le
UPS (consultez la section Fonctionnement de base). Prenez note! Le UPS ne se met-
tra PAS en marche automatiquement au contact de l'alimentation de service.
Commandes et témoins
A
Le bouton " ON/OFF/TEST "
• Pour mettre le UPS en marche : Appuyez et maintenez enfoncé le bouton
ON/OFF/TEST (marche/arrêt/test) pendant une seconde.* S'il n'y a pas d'alimen-
tation de service, appuyer sur le bouton entraînera le démarrage " à froid " du
UPS, c'est-à-dire la mise en marche et l'alimentation à partir de ses piles.**
• Pour éteindre le UPS : Appuyez et maintenez enfoncé le bouton ON/OFF/TEST
(marche/arrêt/test) pendant une seconde.* Le UPS sera complètement éteint (dés-
activé).
• Pour effectuer un auto-test : Avec votre UPS branché et en marche (ON),
appuyez et maintenez enfoncé le bouton ON/OFF/TEST (en marche/arrêt/test)
pendant trois secondes.
ATTENTION ! Pour effectuer un auto-test, vous devez maintenir enfoncé le
bouton ON/OFF/TEST (marche/arrêt/test) en continu pendant trois secondes; si
vous relâchez le bouton trop tôt, cela aura pour effet de désactiver le système
UPS et de couper l'alimentation aux appareils qui y sont branchés. Afin de vous
assurer que vous avez appuyé sur le bouton suffisamment longtemps, ne relâchez
pas le bouton avant d'avoir entendu l'alarme audible du système UPS émettre un
bip deux fois. Le premier bip se fera après une seconde pour indiquer que le UPS
sera désactivé si le bouton est relâché. Le deuxième bip se fera après deux sec-
ondes pour indiquer que le UPS effectuera un auto-test si le bouton est relâché.
Le test durera environ 10 secondes alors que le UPS passera sur la pile pour met-
tre à l'essai sa capacité de charge et de rechargement des piles. Tous les DEL s'al-
lumeront et l'alarme du UPS se fera entendre. Consultez la description des DEL
ci-dessous afin de déterminer le résultat de l'auto-test.
Remarque : vous pouvez laisser l'équipement en fonction pendant un auto-test.
ATTENTION ! Ne débranchez pas votre UPS pour tester ses piles. Vous
enlèveriez la mise à la terre de sécurité et pourriez introduire une surtension qui
endommagerait vos connexions réseau.
L'alarme émettra un bip sonore rapide après une seconde. ** Si complètement chargées.
B
TEMOIN "MARCHE/ARRET" : cette DEL verte reste allumée pour indiquer
que l'onduleur est en marche et alimente votre équipement soit par l'alimentation
de secteur, soit par ses batteries. Si l'alarme sonore se déclenche (4 bips brefs suiv-
is d'une pause), l'onduleur fonctionne à partir de ses batteries.
C
Voyant DEL " SURCHARGE/CONTRÔLE DE BATTERIE " : Ce voyant DEL
rouge s'allume en permanence pour indiquer que la capacité des prises supportées
par les batteries est surchargée. Pour éliminer la surcharge, débrancher une partie de
votre équipement des prises supportées par les batteries, puis utiliser le bouton
ON/OFF/TEST pour exécuter un auto-test. Si l'UPS continue de détecter une sur-
charge, débrancher plus d'équipement; arrêter et répéter le test jusqu'à sa réussite.
ATTENTION! Toute surcharge non corrigée immédiatement par l'utilisateur après
l'auto-test peut entraîner l'arrêt de l'UPS et empêcher l'alimentation électrique en cas
de panne ou de baisse de tension. Le voyant DEL clignote pour indiquer que la bat-
terie a besoin d'être rechargée ou remplacée. Si le voyant DEL clignote (et qu'une
sonnerie d'alarme retentit en permanence) pendant une panne ou une baisse de ten-
sion, les batteries de l'UPS sont presque déchargées; vous devez sauvegarder vos
fichiers et fermer immédiatement votre équipement. Si le voyant DEL clignote à la
suite de l'auto-test de l'UPS (après que l'UPS est en marche), cela pourrait indiquer
que la batterie a besoin d'être remplacée. Laisser l'UPS en charge continue pendant
12h; puis utiliser le bouton ON/OFF/TEST pour exécuter un auto-test. Si le voyant
DEL continue de clignoter, communiquer avec Tripp Lite pour le service. Si votre
UPS nécessite un remplacement de batterie, rendre visite à Tripp Lite sur le Web à
www.tripplite.com/support/battery/index.cfm pour trouver la batterie de remplace-
ment spécifique pour votre UPS.
D
Régulation automatique de tension (interne, non montré) : ajuste automatique-
ment les variations de la tension d'entrée (soustension ou surtension) pour fournir
à l'équipement connecté une alimentation de sortie en 230 V de qualité nécessaire
pour l'équipement informatique ; cette fonction est distincte de l'alimentation de
secours par batteries (les batteries de se déchargent pas).
E
Protection par batteries de secours/Sortie protégée contre les surtensions :
l'équipement peut être alimenté par les batteries et il est protégé contre les surten-
sions. Connectez votre unité centrale, votre écran et les autres équipements essen-
tiels à ces sorties. REMARQUE : NE CONNECTEZ AUCUNE IMPRIMANTE
LASER A CES SORTIES.
F
Sortie de l'entrée c.a : accepte un cordon d'alimentation fourni par l'utilisateur
avec une prise spécifique région.
G
Port de communication USB : Ce port permet de brancher votre UPS à n'importe
quel ordinateur pour des sauvegardes automatiques de fichiers et une interruption
sans surveillance dans l'éventualité d'une panne de courant. À utiliser avec le logi-
ciel PowerAlert de Tripp Lite et un câble approprié USB. Un CD de PowerAlert et
un câble USB pourraient être inclus avec votre UPS; si c'est le cas, insérer le CD
dans le lecteur CD de votre ordinateur et suivre les directives d'installation. Si le
logiciel PowerAlert et le câble approprié ne sont pas joints à votre UPS, vous pou-
vez obtenir le
logiciel GRATUITEMENT par le Web à www.tripplite.com.
N'importe câble USB fourni par l'utilisateur peuvent alors être utilisés pour branch-
er votre UPS à votre ordinateur. REMARQUE : Cette connexion est optionnelle.
L'UPS fonctionnera correctement sans cette connexion.
ATTENTION : Les utilisateurs doivent prendre bien soin de minimiser les
événements électrostatiques. En cas de sévère décharge électrostatique au
port USB ou à proximité, l'onduleur UPS pourrait s'éteindre automatique-
ment. En d'extinction, l'onduleur UPS devra être rallumé.
H
Jacks de protection Tél/DSL : Stoppent les surtensions sur les lignes de téléphone
et de télécopieur. Les modèles INTERNETX750AVR offrent un doubleur intégré
(une prise d'entrée et deux prises de sortie) vous permettent de brancher simultané-
ment deux dispositifs partageant une ligne unique. Le branchement de votre
équipement à ces jacks est optionnel. L'UPS fonctionnera correctement sans cette
connexion.
I
Porte de remplacement de batterie (panneau inférieur, non illustré) : Dans des
conditions normales, la batterie initiale de votre système UPS durera plusieurs
années. Le remplacement de la batterie ne doit être réalisé que par du personnel de
service qualifié. Référez-vous à la rubrique " Mises en garde relatives à la batterie
" à la section Sécurité. Si votre UPS nécessite un remplacement de batterie, rendez
visite à Tripp Lite sur le Web à www.tripplite.com pour trouver la batterie de rem-
placement spécifique à votre UPS.
E2
C
B
A
Garantie
GARANTIE LIMITEE DE 2 ANS
Le vendeur garantit, pour une durée de 2 ans à compter de la date d'achat initiale, que ce produit, sous réserve d'utilisation
conforme aux instructions applicables, est exempt de défauts d'origine pour les pièces et la main d'oeuvre (exception : hors des
Etats-Unis et du Canada, les batteries sont garanties 1 an). En cas de défaut de pièce ou de main d'oeuvre constatée durant
la période de garantie, le vendeur effectuera la réparation ou le remplacement du produit à sa seule discrétion. Le service au
titre de cette garantie ne peut être fourni que si vous livrez ou expédiez le produit (frais d'expédition ou de livraison prépayés)
à l'adresse suivante : Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609 - USA. Les frais d'expédition en retour sont à la charge
du vendeur. Appelez le Service Clientèle de Tripp Lite Customer au numéro +1 (773) 869-1234 avant d'envoyer tout équipement
en réparation.
CETTE GARANTIE NE S'APPLIQUE PAS EN CAS D'USURE NORMALE OU DE DOMMAGES RESULTANT D'ACCIDENT, DE
MAUVAISE UTILISATION, D'USAGE ABUSIF OU DE NEGLIGENCE. LE VENDEUR N'OFFRE AUCUNE GARANTIE
EXPRESSE AUTRE QUE CELLE EXPRESSEMENT SPECIFIEE ICI. SAUF DANS LA MESURE D'UNE INTERDICTION PAR
LA LEGISLATION EN VIGUEUR, TOUTES LES GARANTIES IMPLICITES, Y COMPRIS LES GARANTIES DE QUALITE
MARCHANDE OU D'ADAPTATION A UN USAGE PARTICULIER, SONT LIMITEES A LA DUREE DE LA PERIODE DE
GARANTIE DEFINIE CI-DESSUS ; CETTE GARANTIE EXCLUT EXPRESSEMENT TOUS DOMMAGES ACCESSOIRES OU
INDIRECTS. (Certains Etats n'autorisant pas la limitation de durée des garanties implicites, ou n'autorisant pas l'exclusion ou
la limitation des dommages accessoires ou indirects, les limitations ou exclusions qui précèdent peuvent ne pas s'appliquer à
votre cas. Cette garantie vous donne des droits spécifiques, outre ceux dont vous pouvez bénéficier selon les juridictions).
Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609 - USA.
AVERTISSEMENT : Avant de mettre le produit en service, l'utilisateur doit prendre soin de vérifier qu'il correspond correctement
et en sécurité à l'utilisation prévue. Etant donné l'étendue des applications individuelles possibles, le fabricant ne peut déclarer
ni garantir l'aptitide à l'emploi ni l'adaptation de ces produits à une application spécifique.
Tripp Lite applique une politique d'amélioration permanente. Les caractéristiques techniques peuvent être modifiées sans
préavis.
Numéros d'identification de conformité aux règlements
À des fins de certification et d'identification de conformité aux règlements, votre produit Tripp Lite a reçu un numéro de série
unique. Ce numéro se retrouve sur la plaque signalétique du produit, avec les inscriptions et informations d'approbation req-
uises. Lors d'une demande d'information de conformité pour ce produit, utilisez toujours le numéro de série. Il ne doit pas être
confondu avec le nom de la marque ou le numéro de modèle du produit.
Ce produit a été conçu et fabriqué aux États-Unis.
1111 W. 35th Street, Chicago, IL 60609 USA
(773) 869-1234 • www.tripplite.com
Copyright © 2005 Tripp Lite. All rights reserved.
3
E
D
F
H
loading

Resumen de contenidos para Tripp-Lite AVRX550U

  • Página 1 Installation Installation Owner’s Manual AVRX550U AVRX750U UPS System Not suitable for mobile applications. Important Safety Instructions SAVE THESE INSTRUCTIONS— This manual con- tains instructions and warnings that should be followed STEP 1: Unplug the computer’s power cord from both your AC outlet and the com- ETAPE 1 : Déconnectez le cordon d'alimentation de votre ordinateur de la prise d'al-...
  • Página 2 Äâåðöà äëÿ çàìåíû áàòàðåè (íèæíÿÿ ïàíåëü, íå ïîêàçàíî íà áåñïåðåáîéíîãî ïèòàíèÿ èëëþñòðàöèè): â îáû÷íûõ óñëîâèÿõ ïåðâîíà÷àëüíàÿ áàòàðåÿ â ÈÁÏ (ÈÁÏ) AVRX550U ðàáîòàåò â òå÷åíèå íåñêîëüêèõ ëåò. Åñëèïîíàäîáèòñÿ çàìåíà áàòàðåè â ÈÁÏ, Puerta de reemplazo de la batería (Panel inferior, no mostrado): en condi- ïîñåòèòå...