Newland NLS-HR100L Guia Del Usuario página 38

Tabla de contenido
** Enter Setup
Register
0x0073
Bit
Bit 7-4
Reserved
Bit 3
1: Transmit Standard 25 Check Digit
Bit 2
1: Enable Standard 25 Check Digit
Bit 1
Reserved
Bit 0
1: Enable Standard 25
0x0074
Register
Bit
Bit 7-6
Reserved
Bit 5
1: Enable Code 39 Full ASCII
Bit 4
1: Transmit Code 39 Check Digit
Bit 3
1: Enable Code 39 Check Digit
1: Transmit Code 39 Start/Stop Characters
Bit 2
0: Do Not Transmit Code 39 Start/Stop Characters
Bit 1
Reserved
Bit 0
1: Enable Code 39
Register
0x0075
Bit
Bit 7
Reserved
Bit 6
1: Transmit Codabar Check Digit
Bit 5
1: Enable Codabar Check Digit
Codabar Start/Stop Character Format:
Bit 4-3
00: ABCD/ABCD
10: abcd/abcd
1: Transmit Codabar Start/Stop Characters
Bit 2
0: Do Not Transmit Codabar Start/Stop Characters
Bit 1
Reserved
Bit 0
1: Enable Codabar
Exit Setup
Feature
0: Do Not Transmit Standard 25 Check Digit
0: Disable Standard 25 Check Digit
0: Disable Standard 25
Feature
0: Disable Code 39 Full ASCII
0: Do Not Transmit Code 39 Check Digit
0: Disable Code 39 Check Digit
0: Disable Code 39
Feature
0: Do Not Transmit Codabar Check Digit
0: Disable Codabar Check Digit
01: ABCD/TN*E
11: abcd/tn*e
0: Disable Codabar
34
Tabla de contenido
loading

Este manual también es adecuado para:

Nls-hr100l-70

Tabla de contenido