GB
GB
If the controller is replaced, the remaining capacity of the
filter is no longer detected! Simultaneous filter
replacement is recommended!
Technical Data
• Voltage supply:
• Power consumption:
• Standby power loss:
• Type of protection
– Control unit:
– Mains plug:
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Function of Buttons
Reset remaining filter capacity
Filter size selection
Carbonate hardness adjustment
If no button is actuated for 30 sec or if
voltage supply is disconnected, unsaved
settings will be lost.
Replacing the Controller
• Disconnect voltage supply.
• Replace Controller.
• Reconnect voltage supply.
The display illuminates.
Synchronize Fitting and Control Unit
(Does not apply to Mono versions.)
• Press buttons and hold simultaneously until SE flashes
in the display.
• Press button, until C- flashes in the display.
• Keep pressing or button until H- flashes in the display.
• Press button until H- stops flashing
®
• The Blue
handle synchronization will be started, HC
flashes in the display and the Blue
®
• As soon as the Blue
completely by turning the Blue
40 404 40 430 40 412 40 691 40 547
1.600 l
4.000 l 6.600 l
1,200 l
3,000 l 5,000 l
900 l
2,250 l 3,800 l
600 l
1,500 l 3,000 l
400 l
1,000 l 1,700 l
250 l
650 l
1.600 l
4.000 l 6.500 l
600 l
1,500 l 2,300 l
350 l
1,000 l 1,500 l
250 l
650 l 1,000 l
-
-
-
-
-
-
100 - 240 V AC / 50/60 Hz
®
handle flashes red.
handle flashes green open fitting
®
-Handle.
A
-
-
-
-
-
-
-
-
-
-
1,000 l
-
-
-
-
-
-
-
-
-
-
-
700 l
3,000
-
200 l
3,000
-
90 l
3,000
• As soon as the Blue
fitting by turning the Blue
• Confirm setting by pushing button until HC appears.
The factory-adjusted filter capacity is displayed.
Setting the Filter Size
The control unit of the GROHE Blue
with the 600 litre filter cartridge at the factory.
9 W
• Press the button and hold until the pre-set value flashes
< 1.0 W
in the display (e.g. B. F1)
IP 68
• Tap button until desired cartridge size appears:
IP 40
- F1:
A
- F2:
1,500 litres
- F3:
3,000 litres
2
- F4:
2,500 V
- F5:
1,500 litres
100 °C
- F6:
3,000 litres
- F7:
- F8:
3,000 litres
• Press the button and hold until the select value stops
flashing.
The remaining filter capacity is displayed in per cent.
The litre capacity (A) of the cartridge varies according to the
water hardness set (B) and the size of the cartridge, see table.
Adjust bypass of filterhead (C) according to local
carbonate hardness (B), see documentation of filter and
table.
Set carbonate hardness at control unit (D) volume, See
table.
• Press the button and hold until the pre-set value (e.g. C3,
factory setting) flashes on the digital readout.
• Tap the button and select required value C1 - C6.
• Press the button and hold until the select value stops
flashing.
The remaining filter capacity is displayed again.
Reset Remaining Filter Capacity of Filter Cartridge
• Press button and hold until rF flashes in the display.
• Release the button and press again until rF stops
flashing.
The remaining filter capacity is reset and the factory setting is
displayed.
°KH
°fH
mval/l
7 - 9
12 - 16
2.50 - 3.38
10 - 11
17 - 20
3.39 - 4.09
12 - 13
21 - 24
4.10 - 4.82
14 - 17
25 - 31
4.83 - 6.25
18 - 24
32 - 43
6.26 - 8.75
25 - 35
44 - 63
8.76 - 12.50
≤ 9
≤ 16
≤ 3.38
10 - 24
17 - 43
3.39 - 8.75
25 - 29
44 - 52
8.76 - 10.35
≤ 30
≤ 53
≤ 10.36
®
handle briefly flashes green , close
®
handle, HC flashes in the display.
®
fitting is set for operation
600 litres
40 404 000
40 430 000
40 412 000
600 litres
40 404 001
40 430 001
40 412 001
600 litres
40 691 001 (magnesium)
40 547 001 (activated carbon)
B
mmol/l
1.25 - 1.69
1.7 - 2.05
2.06 - 2.41
2.42 - 3.12
3.13 - 4.37
4.38 - 6.24
≤ 1.69
1.7 - 4.37
4.38 - 5.22
≤ 5.33
≤ 9 (°dGH)
26 - 35 (°dGH)
≥ 36 (°dGH)
C
D
70%
C6
60%
C5
50%
C4
40%
C3
30%
C2
20%
C1
3
C4
2
C3
1
C2
0
C1
3
C3
2
C2
1
C1
2