Miswire – Single or multiple conductors are not connected to the same pins at both ends of the cable.
With a remote attached, the wire map shows the pin numbers from display line 1 (main) to display line 2
(remote). A reverse pair is a special case of a miswire in which the pair is wired to the correct pair of pins,
but the two conductors are reversed. In CABLE TEST (no remote), this type of error is not detectable.
Split Pair – A split pair occurs when a cable is terminated consistently at both ends, but in the
2
wrong order. Twisted pair cables typically are made up of eight wires twisted together in 4 pairs.
These 4 pairs are designated as pairs by the wiring standards and are intended to carry a signal by
creating a circuit. 1 & 2, 3 & 6, 4 & 5 and 7 & 8 are the pairs designated by T568A/B for a RJ45
jack or plug. A cable can be wired with correct continuity but not with correct pairing. With remote
attached, the pin numbers split pairs flash and an error message is displayed listing the split pair
pin numbers. In the PRETEST mode (no remote), the Error message is displayed.