2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
5. Before starting the equipment
5.1 Using the equipment correctly
•
The pressure cleaner must be stood on a le-
vel, stable surface.
•
It is recommended that you adopt the correct
operating position every time you use the
equipment, with one hand on the gun and the
other on the lance.
•
Never direct the water jet at electrical lines or
the equipment itself.
•
So that the pump does not suffer any damage
when it is not in use, a small amount of leaka-
ge from the pump is normal.
•
Never use the machine in potentially explosi-
ve areas under any circumstances!
•
The operating temperature must be between
+5 and + 40°C.
•
Do not cover or modify the lance or the spray
nozzles in any way.
•
The pressure cleaner is designed to be used
with cold or lukewarm water; higher tempera-
tures can damage the pump.
•
Do not use water that is dirty, gritty or con-
tains any chemical products, as these could
impair operation and shorten the life of the
equipment.
Caution: Risk of explosion
Do not spray fl ammable liquids.
Warning
Water that has passed through the non-return
valve is not drinkable.
Warning
If cleaning agent gets into contact with your skin
or into your eye, rinse immediately with lots of
clean water. Then consult a doctor or follow the
steps described on the safety data sheet or provi-
ded by the manufacturer of the cleaning agent.
Anl_RB_HP_1334_Arg_SPK7.indb 17
Anl_RB_HP_1334_Arg_SPK7.indb 17
GB
5.2 Assembly
5.2.1 Assembling the equipment (Fig. 1)
Push the accessories holder (2) onto the high-
pressure cleaner (5). The holder can be used for
space-saving storage of the gun (8), the extensi-
on (9) and the high-pressure hose (14).
Note! Before using the pressure cleaner, make
sure that the high-pressure hose is completely
unwound.
5.2.2 Fitting the attachments (Fig. 2)
Before you use the high-pressure cleaner (5) you
must fi rst fasten the extension (9) to the gun (8)
by pushing and twisting.
Then push the rotating nozzle (13) or the cleaning
agent container (10) onto the extension (9) by
means of the quick connection system.
Rotating nozzle
To remove particularly stubborn dirt, use the rota-
ting nozzle (13).
Cleaning agent container
You can adjust the quantity of cleaning agent you
want to add by turning (+ / -) on the setting wheel
(11). We recommend using the cleaning agent
sparingly.
5.2.3 Connecting the high-pressure hose
(Fig. 3/4)
Connect the high-pressure hose (14) to the gun
(8) and the high-pressure cleaner (5).
Note:
The connections for the high-pressure hose
and the accessories are equipped with a quick
connection system (12). To connect, simply push
the hose or the accessory onto the respective
connection. To remove, simply actuate the quick
connection system (12) and you can remove the
hose or the accessory.
Each time before fi tting, always check that the
quick connection system (12) is correctly enga-
ged. Do this by pulling briefl y on the hose or the
accessory.
- 17 -
03.05.16 16:33
03.05.16 16:33