It is necessary to install the photocell 1 properly, in order to cover the action space of the gate.
no
the opening of PHOTO1 is not available
APCh the opening of PHOTO 1 is available for the connection of the photocell
Cost
the opening of PHOTO 1 is available for the connection of the rib.
INPUT STOP
This menu permits to select the functions associated to the
command of STOP.
no
the input STOP is not available
ProS
the input STOP stops the gate: pressing the command
START the gate continues the motion
invE
the command STOP stops the gate: at the next START the
gate starts moving in the opposite direction.
NOTE: During the pause STOP stops the gate: pressing the
command START will always re-closing the gate.
INPUT PHOTO 1
This input can be activated for the connection of two different
safety devices: the photocell or the rib. The rib (contact normally
closed) is an active safety device in opening and closing (now
active during the backlash): its intervention during the opening
phase stops the gate, inverts the motion for 4 s, without offsetting
the doors. On the other hand, the intervention of the rib in closing
phase stops the gate, inverts the motion with the offset of the
doors. The photocell 1 (contact normally closed) is an active
security in opening and closing: the intervention of the photocell
during the closing stops the gate, at its disengagement the gate
inverts the motion.
Differently the intervention of the photocell in opening stops the
gate, at its disengagement the gate starts opening again.
INPUT PHOTO 2
The photocell 2 is active in closing: if it is dimmed during the
closing it stops the gate and inverts the motion. The option CFCh
activates the photocell even when the gate is still: closed gate
means that no impulse has been given, either it is in pause or it
has received a STOP command. In this case through all the time
of the darkening of the photocell the control unit does not receive
any command of activation at any opening / closing cycle.
no
the input PHOTO 2 is not available
CFCh
the input PHOTO 2 is available: the photocell is active in
closing and also when the gate is still
Ch
the input PHOTO 2 is available: the photocell is active
only during the closing
24