Secura QLT15 Manual Del Usuario página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
2
Mount to Wall
Solid concrete or concrete block
2-1
Mark the wall
[01]
2-2
Drill pilot holes
2-3
Insert anchors and lag bolts
[06]
[06]
6910-002038 <01>
406 mm
(16 in.)
[04]
Level the wall plate [01] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage!
Mount the wall plate [01] directly onto the concrete surface.
Minimum solid concrete thickness: 203 mm (8 in.).
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16 in.).
Minimum horizontal space between fasteners: 406 mm (16 in.).
Drill pilot holes as illustrated.
CAUTION:
Pilot holes MUST be drilled to a depth of 75 mm (3 in.) using a
10 mm (3/8 in.) diameter drill bit.
Never drill into the mortar between blocks.
75 mm
(3 in.)
Insert lag bolt anchors [06]. Then insert lag bolts [04] through the
washers [05], wall plate [01], and then into the anchors.
CAUTION:
Improper use could reduce the holding power of the lag bolt. To
avoid potential injuries or property damage:
[01]
[05]
13 mm
(1/2 in.)
Avoid potential injuries or property damage! :
Avoid potential injuries or property damage!
Be sure the anchors [06]
are seated fl ush with the
concrete surface.
Tighten the lag bolts [04]
only until the washers
[05] are pulled fi rmly
against the wall plate
[01].
DO NOT over-tighten
the lag bolts [04].
10 mm
(3/8 in.)
7
Tabla de contenido
loading

Tabla de contenido