Hopper Dumping - Advance Proterra GPL Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

HOPPER DUMPING

DANGER!
The hopper must be emptied on level grounds only.
Do not lift the hopper when the machine is on incline.
NOTE
The minimum ceiling height dumping clearance required for lifting the hopper is 108.2 in (275 cm).
1.
Lift the main broom with the lever (53).
2.
Press the lower part of the switch (68) to turn on the filter shaker and remove the excess dirt from the dust filter (12).
NOTE
Always run the filter shaker with the hopper fully lowered.
3.
Drive the machine to the area appointed to empty the hopper, or close to a large trash receptacle.
4.
Lift the hopper with the lever (54) to the desired dump height.
NOTE
The dumping door automatically closes when using the lever (54) to lift the hopper. The control of the dumping door can
be regained with the lever (55) as soon as the hopper begins to lift so that it can be dumped at any height as necessary.
5.
Move the machine forward until the hopper is over the receptacle and engage the parking brake.
6.
Open the dumping door with the lever (55) and dump the hopper.
NOTE
If not dumping into a trash receptacle, low dumping is recommended to help avoid airborne dust.
WARNING!
Before performing any maintenance procedure under or near to the lifted hopper, fully lift the hopper with the
lever (54), then pull the handle (39) backwards to make sure that the hopper safety support (5) is in place. The
hopper safety support holds the hopper lifted to allow working under the hopper. Never rely on the machine's
hydraulic components to safely support the hopper.
7.
Pull the locking handle (39) to make sure the hopper safety support (5) is in place, then slightly lower the hopper with the lever
(54) to secure it.
8.
Check the hopper door and its front gasket. If necessary, use a brush to remove litter from these areas.
For machine proper operation, the hopper door must seal tightly against the broom housing.
9.
Return to the operator's compartment. Disengage the parking brake. Move the machine back until the hopper will clear the
receptacle.
10. Lift the hopper with the lever (54), pull the locking handle (39) forward until the safety support (5) disengages, then lower the
hopper.
INSTRUCTION FOR USE
33019864 - Proterra™
ENGLISH
19
Tabla de contenido
loading

Este manual también es adecuado para:

Proterra gpl br

Tabla de contenido