ES-HD-IPM : AVAILABLE MODELS AND FEATURES
Operating temperature
-10°C / +60°C
(14°F / 140°F)
-10°C / +50°C
(14°F / 122 F°)
-30°C / +50°C
(-22°F / +122°F)
Tab. 2
8 Switching on
The automatic pre-heating (de-ice) process
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at
low temperatures. The duration ranges
between 60 and 120 minutes, depending
on conditions.
During the lighting phase the device reads the
status of the dip switch and automatically detects
all the connected options for the correct energy
management of the housing.
The 6 LEDs shown in the figure allow to check the
product's operating status.
Fig. 6
Refer to the table to identify the operating status.
Injector
Camera
PoE classe 3 (13W)
PoE max. class 2 (7W)
Hi-PoE class 4 (25W)
PoE max. class 3 (13W)
PoE classe 3 (13W)
PoE max. class 2 (7W)
Hi-PoE class 4 (25W)
PoE max. class 3 (13W)
Hi-PoE class 4 (25W)
PoE max. class 3 (13W)
Hi-PoE class 4 (25W)
PoE max. class 3 (13W)
Heating
–
–
–
–
✓
✓
OPERATING STATUS
LED
LED
Status
LD1 (Po-
Off
wer)
On
LD2
Off
(Camera)
On
1 flashing
2 flashings
5 flashings
9 flashings
LD3 (Not used)
LD4 (He-
Off
ater)
1 flashing
On
LD5 (Not used)
LD6
Off
(Cold Start)
1 flashing
On
Tab. 3
Fan with double air
filter
✓
✓
–
–
–
–
Apparatus Status
The device is not powered
The device is correctly
powered
The camera is not connected
or Cold Start is active
The camera is correctly
powered
The camera has a low identifi-
cation resistance
The camera has a high identi-
fication resistance
The camera has an excessive
energy consumption
The camera requires more
energy than the available
Heating is not available or po-
wer available is not sufficient
Heating is inactive
Heating is active
Heating is not available
The pre-heating procedure is
inactive
The pre-heating procedure is
underway