15 Positioning the Lamp
The size of the cone of light is adjusted via the
distance to the bond. Light performance reduces
with increasing distance, which also increases
curing times
* measured with the UVA measuring device BO 5500300
16
ca. Ø 7 cm
(approx. Ø 2-3/4")
ca. Ø 9,5 cm
(approx. Ø 3-3/4")
ca. Ø 12 cm
(approx. Ø 4-3/8")
365nm
395nm
Distance [cm]
16 External Control
TwinLED is equipped with an external control
connection, e.g. for semi-automated processes.
Do not hesitate to contact us if you are interested.
17 Changing the Battery
A new battery is available with the art. no.
SP BT5559.
Loosen the four Phillips screws and lift the cover.
Remove the battery from the device and insert a
new battery.
When putting back the cover, make sure the gasket
is in the correct position. Then screw-fix the cover
with the four Phillips screws.
Please correctly dispose of used batteries.
Please also take into consideration the notes in
the "Disposal" paragraph of these operating
instructions.