Hiltron security XR152 Guia De Inicio Rapido página 4

Idiomas disponibles

Idiomas disponibles

XR152 - Passive infrared radio XR Series detector
CONFIGURATION
Press and hold the two buttons until both LEDs are lit, then release.
Enter the area code using the left button for one (1) and the right for zero (0).
Zone 2:
0 0 0
Zone 3:
1 0 0
Zone 4:
0 1 0
Zone 5
1 1 0
Zone 6
0 0 1
Zone 7
1 0 1
Zone 8
0 1 1
Zone 9
1 1 1
Then enter the 18-digit terminal code, checking that the green LED lights up for one (left button) and the red LED for
zero (right button).
If the configuration is successful, the two LEDs will light up instantaneously.
Attention : if you enter a terminal code containing a sequence of all ones or all zeros, the XR152 will produce an error signal
and both LEDs will flash simultaneously to indicate an error.
SENSITIVITY SETTING
Press and hold the left button on the XR152 for a few seconds until the red LED lights up, then release it. The green LED will
light up each time the sensor detects movement, but will not trigger the alarm on the base unit. This allows you to set the
device to the desired sensitivity (turn trimmer clockwise to increase sensitvity); for a reliable configuration, make sure to
replace the cover each time it is changed and ensure that the lens is positioned correctly on the pyroelectric sensor.
To interrupt the test phase, press both buttons simultaneously until both LEDs light-up; otherwise, wait until the test is
completed (5 minutes).
FUNCTION TEST
Press and hold the right button for a few seconds until the green LED lights up; this will start the sensor test phase, and
enables the XR series to send signals to the base unit.
During this phase, the transmission interval time (5 min.) is deactivated and the sensor transmits at each detection. To
interrupt the test phase, press both buttons simultaneously until both LEDs light-up; otherwise, wait until the test is completed
(5 minutes).
LOW BATTERY WARNING
Each time the contact is opened::
Green LED: working correctly
Red LED: battery empty
Warning
In the case of using the XR1600, or PROTEC8GSM/TM800GSM central units, the code is:
Code XR1600
000 - Zone 0
001 - Zone 1
010 - Zone 2
011 - Zone 3
100 - Zone 4
101 - Zone 5
110 - Zone 6
111 - Zone 7
4
+
System code
+
System code
+
System code
}
+
System code
+
System code
+
System code
+
System code
+
System code
Code PROTEC4GSM/PROTEC8GSM/TM800GSM
000 = zone 1
100 = zone 2
010 = zone 3
110 = zone 4
001 = zone 5
101 = zone 6
011 = zone 7
111 = zone 8
XR500 anti-theft central unit
will not recognize these zones
because it handles up to 3
zones via radio.
security
"1"
"0"
loading