UK
Fully illustrated step by step instructions are
downloadable on www.saniflo.co.uk
1
DESCRIPTION
Eco is a WC specially designed with an inte-
®
SANICOMPACT
gral pump/macerator. SANICOMPACT
use.
Installed and used correctly, SANICOMPACT
consistent and reliable service.
Please note the following warning signs:
"
" Possible danger to personnel,
"
" Warning of possible electrical hazard.
"WARNING" This is a general warning that failure to
follow instructions could result in poor functioning
of the unit.
OPERATING PRINCIPLE
Eco is controlled by an electronic
®
SANICOMPACT
programmer.
It has a macerating and pumping function. To start press
one of the two grey sides (light grey: small flush, dark grey:
large flush) of the button integrated to the bowl.
2
LIST OF ACCESSORIES INCLUDED
3
DIMENSIONS
4
TECHNICAL DATA
Applications
Type
Maximum Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption
Electric Class
Degree of protection
Maximum water temperature
Net Weight
Only installations conforming to the above
WARNING:
specifications are acceptable.
5
PERFORMANCE CURVE
6
INSTALLATION
6a
ATTACHING THE TOILET TO THE FLOOR
Place the SANICOMPACT
Trace round the position of the bowl and mark the postition
of the fixing screws. Remove the bowl and then mark the
position of the fixing brackets 15mm inside the drawn line
(see dia
).
6a
Remove the toilet bowl.
Drill through the flooring.
If necessary, and if you have time, lay a silicone joint
around the location of the toilet bowl.
Install the fixing screws and brackets. Put the
Eco in place. Use the screws to fix the
®
SANICOMPACT
Eco to the floor.
®
SANICOMPACT
Eco is for domestic
®
Eco will give
®
discharge of a WC
CR15 DF
3 m
220-240 V
50 Hz
550 W
2,5 A
I
IP44
35°C
C3
28,6 Kg
C5
29,0 Kg
C6
26,5 Kg
C43
23,2 Kg
C48
25,4 Kg
Eco in the desired location.
®
6b
CONNECTION OF THE DISCHARGE
1 - Fully insert the elbow
waste tube, after turning it to face in the desired
direction.
2 - Fix the base of the elbow
rubber waste tube with a clamp
3 – Connect the sleeve
H
the clamp
. Cut off the end of the sleeve to adapt it to
D
the waste pipe. Connect the 32mm wastepipe into the
sleeve and secure with jubilee clip
4 -
Ensure that you do not twist the discharge
Warning:
pipework inside the unit.
5 -
The horizontal portion of the discharge pipe
Warning:
should be installed in a gravity flow, (1/4 inch to 1 foot).
Avoid any low parts in the discharge pipe.
6 -
Protect pipes against freezing with appropriate
Warning:
insulation. If the toilet is installed in an unheated location
during freezing periods protect it as follows:
• Shut off the water supply,
• Activate one cycle without water,
• Pour antifreeze in the bowl (2 litres),
• Flush the toilet.
7 -
Any bends in the discharge pipe run should be
Warning:
smooth radius bends. If using plastic pipe two 45 degree
offsets can be used to form a smooth bend.
8 -
We would recommend that a drain-off point is
Note:
installed to allow the discharge pipework to be drained
down before any service work.
9 -
To avoid siphoning, install a an anti-siphon valve
Note:
at the high point of the installation.
6c
CONNECTION TO THE WATER SUPPLY
Connect the water supply hose to a shut off valve
Caution: The quality of the rinsing of the bowl depends on
the water pressure.
for a correct rinsing, the water pressure should
WARNING:
be at least 25 PSI (1,7 bars).
In an area where water is not pure (dirty, sandy), we
Note:
advise you to add a filter between the shut off valve and the
toilet to prevent clogging of the solenoid valve.
6d
CONNECTION TO THE ELECTRICAL SUPPLY
The electrical installation should be carried by a
qualified person.
All wiring must conform to BS7671, 1992 requirements for
electrical installation. The unit requires a 220/240 V single
phase AC 50 Hz supply (UK specification). Do not connect
the unit to a conventional plug and socket. The unit should
be connected to a fully earthed electrical supply (class 1).
It must be wired into an unswitched fused fixed wiring
connector protected by a 5 amp fuse and a residual current
detector (30 mA). This connection must be used exclusively
for supplying the unit.
The wires in the mains lead are coloured in accordance
with the following code:
Brown
–
Blue
–
Green/Yellow
–
Ensure the electricity is turned OFF at the main
WARNING:
switch board before wiring to connector. All work on cable,
pressure chamber and motor should only be carried out by
a qualified Saniflo servicing agent, as special tools are
required.
in the end of the rubber
H
a
and tighten it on the
H
a
.
D
to the end of the elbow with
b
.
C
Live
Neutral
Earth