Overview
1
2
3
4
5
6
7
lid
1
wall bracket
2
overflow connection Ø32
3
floater connection
4
water tank
5
support frame
6
adjustable leg (4 legs)
7
filling hose
8
8
Installation
Set up Service Station 300 system near floor drain or in a
liquid containment area!
For the installation are min. two people necessary.
1.
Level the support frame using the adjustable legs.
2.
Place the water tank on the frame.
3.
Secure the tank to the wall.
4.
Connect the provided hose from the floater connection to the
existing tap.
5.
Close the filling hose and fill the tank with clean water.
6.
Adjust if necessary the floater-ball.
7.
Close the water tank with the lid.
8.
Connect if necessary the overflow to the sewer.
9.
Make sure there are no leaks after the installation.
The connection to the water system must be made by a
locally Installer.
Technische Informationen
Service station 300
Water tank width
Total height
Water tank depth
Water tank capacity
Empty weight
Weight filled
cm
114
cm
223.7 - 225
cm
60
l
300
kg
55
355
kg