Operation - Thetford SaniCon Turbo 300 Manual Del Propietário

Ocultar thumbs Ver también para SaniCon Turbo 300:
Overview
Congratulations on your purchase of the Sani-Con® 300 - the
cleanest, most sanitary, and convenient way to empty your RV
holding tank!
Read and understand the warnings listed in this docu-
AVISO
AVIS
NOTICE
!
!
!
!
ATTENTION
CAUTION
ATENCIÓN
DANGER
ment before you operate or service this system. If you do
ATTENTION
ATTENTION
ATTENTION
not obey these warnings there is a risk of property loss,
injury, or electrocution. Do not make any changes to this
unit as this could result in property damage, injury, or
electrocution.
Thetford Corporation accepts no responsibility or liability for
damage to equipment, injury, or death that may result from the
system's improper installation, service, or operation.
Thetford Corporation recommends that plumbing and electrical
work be performed by a licensed tradesperson. Local permit and
code compliance is required.
Cautions and Warnings
Read and understand the warnings and cautions listed in this
document before you operate, or service this unit.
Wear appropriate personal protective equipment when
AVIS
NOTICE
AVISO
!
!
!
!
CAUTION
ATENCIÓN
DANGER
ATTENTION
using the Sani-Con® system.
ATTENTION
ATTENTION
ATTENTION
Do not make any changes to this unit, as this could
AVISO
AVIS
NOTICE
!
CAUTION
result in property damage or injury.
Flush only organic human waste and toilet tissue.
Do not flush non-dissolving articles such as feminine
hygiene products, paper towels, or moist towelettes,
as this will damage the macerator and will void your
warranty.
To avoid pump failure, if you are using an accessory
garden hose on the end of the nozzle, make sure
that the inner diameter of the hose is .75 " (1.9 cm) or
greater.
Questions?
If you have any questions or need assistance, please contact
Customer Service at 1-800-543-1219, available Monday through
Friday 8 a.m. to 6 p.m., Eastern Standard Time.

Operation

To extend the life of the discharge hose
NOTICE
sharp bends and stress at hose cuffs and support the
hose within 2"- 5" of cuff
www.thetford.com
,
(K2)
avoid
when in use.
(K2.1)
Attach Pump to RV
Refer to Fig. 1 and Fig. 5.
(K1)
1.
Remove pump
2.
Remove bayonet cap
3.
Connect the bayonet adapter
(5A)
outlet
.
4.
Unscrew large nozzle cap
5.
Attach universal nozzle
Verify SaniCon pump switch is in the off position!
AVISO
AVIS
NOTICE
!
!
!
!
ATTENTION
ATENCIÓN
CAUTION
DANGER
ATTENTION
ATTENTION
ATTENTION
(K1)
6.
Connect pump
(K5)
ligator clips
or quick connect
a 35 AMP, 12 VDC power source:
■ Connect the black alligator clip to the negative post on
the power source.
■ Connect the red alligator clip to the positive post on the
power source.
7.
Using the quick connect
the pre-wired electrical leads (refer to "Connect Electrical -
Quick Connect Option" section).
EMPTY BLACK WATER TANK
Refer to Fig. 1 and Fig. 5.
1. ENSURE universal nozzle (
station! Refer to "Attach Pump to RV" procedure.
TIP For Cleaner Storage: Emptying the black water tank
NOTICE
first, allows gray water to cleanse the system.
2. Open black water tank gate valve (
3. Turn pump on.
4. Do not leave unit unattended.
5. Turn pump off.
TIP: The hose expands as fluid moves to dump station
NOTICE
and contracts when tank is empty.
6. Close black water tank gate valve (
7
(K7)
from storage box
.
(K6)
(K1)
from the pump
.
(K1.3)
to the RV's drain
(K2.4)
.
(K2)
to dump station.
(4A)
to the power source
with the al-
(K3)
, if installed. Using
(K3)
(K1)
, plug the pump
K2
) is securely attached to dump
5B
).
5B
).
Sani-Con Model 300 - Portable Tank "Buddy"
into

Capítulos

Solución de problemas

loading