  • Página 1 USER’S MANUAL...
  • Página 3 Caution Please take a moment to carefully go through the installation guide. Phanteks will not take responsibility for any damages incurred due to incorrect installation and incorrect usage of this product. Thank you.
  • Página 4: Tabla De Contenido

    TABLE OF CONTENTS SPECIFICATIONS ..........................................EXPLODED VIEW ..........................................ACCESSORIES ............................................BRACKETS ............................................. FRONT PANEL LED REMOVAL AND INSTALLATION ............................... I/O PORTS ............................................CONNECTIONS ........................................... PANEL REMOVAL ..........................................MOTHERBOARD INSTALLATION ....................................10. POWER SUPPLY INSTALLATION ....................................11. FILTERS REMOVAL ..........................................12. FANS COMPATIBILITY ........................................13.
  • Página 5: Specifications

    1. SPECIFICATIONS CASE SPECIFICATIONS PH-F140SP (included) Dimension Speed (rpm) 230 mm x 450 mm x 400 mm (W x H x D) 1200 ± 250 rpm Form Factor Max Airflow Micro Tower 82.1 CFM Material(s) Aluminum exterior, Steel chassis Static Pressure 1.33mm H2O Motherboard support uATX, mITX...
  • Página 6: Exploded View

    2. Window Left Side Panel 3. Right Side Panel 4. Front Panel 5. ODD Cover 6. ODD Bracket 7. Top Panel 8. Phanteks Logo Plate 9. Front Dust Filter 10. Hard Drive Cage 11. HDD Trays 12. SSD Bracket (1x) 13. PH-F140 14.
  • Página 7 7. Pannello superiore 7. Panel superior 8. Plaque du logo Phanteks 8. Piastra logo Phanteks 8. Placa con logotipo de Phanteks 9. Filtres à poussière avant 9. Filtro antipolvere anteriore 9. Filtro de polvo frontal 10. Boîtier du disque dur 10.
  • Página 8: Accessories

    3. ACCESSORIES ITEM DESCRIPTION ITEM DESCRIPTION Motherboard/ Screw M3 x 5mm Screw 5 x 10KT Fan installation ODD/SSD Pumpbracket / Motherboard CM6 #5 Side bracket: HDD Screw 6-32 x 6mm CM5.3*10*7*3 Side bracket: SSD Thumb Screws HDD lock (HDD cage) Screw M4 x 8mm Reservoir 9*20mm...
  • Página 9: Brackets

    4. BRACKETS SSD Bracket PWM Hub Le hub PWM Support SSD PWM-Hub SSD-Halterung L’hub PWM Staffa SSD O PWM Hub Suporte do SSD El conector de modulación Soporte de unidad de estado sólido PWM Hub SSD beugel ODD Bracket Crochet ODD Halterung für optisches Laufwerk Staffa ODD Soporte de unidad de disco óptico...
  • Página 10: Front Panel Led Removal And Installation

    5. FRONT PANEL LED REMOVAL AND INSTALLATION Remove the front panel and push in the two tabs on the side of the connector and pulll out out the LED. Once the LED is off, simply plug the new LED into the connector. Retirez le panneau avant et poussez les deux languettes sur le côté...
  • Página 11: I/O Ports

    6. I/O PORTS 1. Power Button 1. Ein-/Austaste 2. Power Reset Button 2. Reset 3. Headphone 3. Kopfhörer 4. Microphone 4. Mikrofon 5. USB 3.0 5. USB 3.0 1. Bouton d’alimentation 1. Botão de Alimentação 2. Réinitialisation de l’alimentation 2. Redefinição de Energia 3.
  • Página 12: Connections

    7. CONNECTIONS USB 3.0 AUDIO PANEL Power LED + Reset SW MIC2 L AGND IntA P2_D+ Power LED - IntA P2_D- MIC2 R IntA P1_D+ AVCC IntA P1_D- FRO-R MIC2_JD IntA P2_SSTX+ F_IO_SEN Power SW H.D.D LED IntA P2_SSTX- IntA P1_SSTX+ LINE2_JD FRO-L IntA P1_SSTX-...
  • Página 13: Panel Removal

    8. PANEL REMOVAL 1. Pull from the front and fully swing the panel out. 2. Push up to remove from the hinge and remove. 1. Tirez depuis l'avant et faites tourner le panneau complètement pour le sortir. 2. Poussez vers le haut pour le retirer de l'articulation et l'enlever. 1.
  • Página 14 8. PANEL REMOVAL To remove the top panel, place your hands on the area shown in the diagram and pull up. For the front panel, place your hands on the area shown and pull outward. Pour enlever le panneau supérieur, placez vos mains sur la zone affichée sur le diagramme et tirez vers le haut.
  • Página 15: Motherboard Installation

    9. MOTHERBOARD INSTALLATION Standoff screws are pre-installed for micro ATX. Les vis du support sont préinstallées pour micro ATX. Abstandhalterschrauben sind bei micro ATX vorinstalliert. Le viti dei distanziatori sono installate precedentemente per micro ATX. Os parafusos separadores estão pré-instalados no modelo micro ATX. Los tornillos separadores vienen preinstalados para micro ATX.
  • Página 16: Power Supply Installation

    10. POWER SUPPLY INSTALLATION REAR VIEW Use the provided screws to secure the PSU in place. (4x) Utilisez les vis fournies pour fixer le bloc d’alimentation en place. Befestigen Sie das Netzteil mit den mitgelieferten Schrauben. Utilizzare le viti fornite per fissare la PSU in sito. Use os parafusos para fixar a Unidade de Proteção e de Comutação.
  • Página 17: Filters Removal

    11. FILTERS REMOVAL To clean the dust filters, run slow moving water through the filters. Dry filters before reinstalling. Pour nettoyer les filtres à poussière, faites couler de l’ e au sur les filtres. Séchez les filtres avant de réinstaller. Reinigen Sie die Staubfilter, indem Sie sie unter langsam fließendem Wasser abspülen.
  • Página 18: Fans Compatibility

    12. FAN COMPATIBILITY FAN COMPATIBILITY TABLE 200mm 140mm 120mm Front (1x included) Rear (Top) (1x included)
  • Página 19: Odd Bracket Installation

    13. ODD BRACKET INSTALLATION ODD INSTALLATION First remove the back plate by unscrewing the two screws. Align the ODD bracket with the mounting holes and screw to hold in place. Enlevez d'abord la plaque arrière en dévissant les deux vis. Alignez le crochet ODD avec les trous de montage et vissez pour fixer.
  • Página 20: Hard Drive Cage

    14. HARD DRIVE CAGE 3.5” INSTALLATION HDD BRACKET REMOVAL Unscrew the 8x screws to remove the HDD Cage. Place hard drive into tray and push in the arms to lock. Placez le disque dur dans le logement et poussez les bras pour le verrouiller. Bringen Sie die Festplatten im Fach an und drücken die Arme zum Verriegeln hinein.
  • Página 21: Drop-N-Lock Ssd Bracket

    15. DROP-N-LOCK SSD BRACKET SSD INSTALLATION Slide in the SSD and screw in from the side to lock in place. Faites coulisser le disque SSD et vissez-le depuis le côté pour le verrouiller dans son emplacement. Schieben Sie die SSD ein und fixieren Sie diese seitlich mit Schrauben. Far scorre l’unità...
  • Página 22: Multifunctional Side Bracket

    16. MULTIFUNCTIONAL SIDE BRACKET SSD mounting hole HDD mounting hole Reservoir Pump Bracket mounting hole mounting hole...
  • Página 23: Watercooling Installation

    17. WATERCOOLING INSTALLATION WATERCOOLING RADIATOR COMPATIBILITY 120mm, 140mm 240mm, 280mm 140mm 120mm 120mm, 140mm 240mm...
  • Página 24 17. WATERCOOLING INSTALLATION 120 MM FORM FACTOR RADIATORS *Caution: Supported Radiator size and thickness varies depending on your setup. Radiator Size Front Rear *Avertissement : Les tailles de radiateur et les épaisseurs supportées varient en fonction de votre Taille de radiateur Avant Arrière Dessus...
  • Página 25: Pwm Hub Installation

    30W in total. Important Note: Please visit our website for multi-language instructions regarding PWM Hub at www.phanteks.com. 1 motherboard connector can only read 1 RPM signal. Therefore, the motherboard will only read the RPM signal from 1 device connected to Fan 1. The RPM form all other devices will be regulated according to FAN 1.
  • Página 26 Verbindung mit 4-pol. CPU-Lüfteranschluss (CPU_Fan) Raccordement des 4 broches au CPU_VENTILATEUR Für einen vollen PWM-Funktionsumfang ist es für den PWM-Hub von Phanteks erforderlich, dass der 4-pol. Stecker Pour une fonctionnalité MLI complète, le concentrateur MLI de Phanteks nécessite de raccorder le con- mit dem CPU-Lüfteranschluss (“CPU_Fan”) am Motherboard verbunden wird, denn alle Motherboard-Hersteller...
  • Página 27 Collegamento del connettore a 4 pin al connettore CPU_FAN Para uma total funcionalidade PWM, o cubo PWM da Phanteks requer que os usuários conectem o conector Per la completa funzionalità PWM, l’hub PWM Phanteks richiede il collegamento del connettore a 4 pin de 4-pin ao conector do "CPU_Fan"...
  • Página 28 Conectando 4-pin ao CPU_FAN De 4-pin aansluiten op CPU_FAN Para uma total funcionalidade PWM, o cubo PWM da Phanteks requer que os usuários conectem o Voor volledige PWM functie wordt vereist dat de 4-pin connector aangesloten wordt op de “CPU_Fan”...
  • Página 29: Pump Bracket

    19. PUMP BRACKET PUMP BRACKET 6#-32 rubber dampers 4.5mm *in millimeters Remove the midplate cover by unscrewing the thumbscrews to install the pump bracket in the HDD area. Pump bracket with universal mounting allows for multiple pumps to be installed. Retirez la plaque du milieu en dévissant les vis à...
  • Página 30: Support And Services

    20. SERVICES AND SUPPORT If you have any questions or concerns, please visit Phanteks’ website for technical support. We consider customer support, satisfaction and feedback an essential element of our overall marketing effort. Please feel free to contact our support team. Thank you! Contact Us at: www.phanteks.com...