Converter for permanent contact CVI34 –
5454806
Functions
This module makes it possible to control one or more window
shutters (or curtains) through the contact of a timer, twilight
sensor, or anemometer.
The module generates 3 pulses upon closing of the contact and 4
pulses upon opening. The pulses will control the MVR500E and
MVR500ER, modules for window shutters, respectively upon
opening and closing.
Additional functions
If the timer contact is normally closed (NC), instead of normally open (NA), it will be necessary to invert the impulse trains generated.
To do this, short press 20 times with a pushbutton temporarily connected to the module's pushbutton input.
Functional diagram
input:
terminal BP
contact
open
output:
terminal C2
3 pulses
The number of pulses generated is, by default, equal to 3 and 4, in order to control the opening and closing of the window shutters.
In more detail, let's say X is the number of pulses generated at the closing of the contact (default: 3) and Y the number of pulses
generated at its reopening (default: 4)
The installer can modify the value of X and Y to create particular controls.
For example, if the user wants to:
•
open the shutters to an intermediate position in the morning, when the twilight sensor closes.
•
leave the shutters in their position when the contact opens in the evening (the user wants to close the shutters manually).
In this case, it is necessary to set X = 2 and Y = 0.
To set X and Y, short press the pushbutton temporarily connected to the pushbutton terminal.
Above all, release the module by short pressing 23 times.
Then short press 25 times to prepare for the insertion of X. Insert the value of X with the number of presses as indicated in the table (in
the case of X = 2, short press 12 times).
Short press 26 times before inserting Y. Insert Y (to insert Y = 0, short press 10 times).
Once the configuration is complete, lock the module with 21 short presses.
MODULE CONFIGURATION TABLE
------ configuring the pulses (X or Y) -------
Number of
Presses (1) Pulses X or Y (4)
10
0
11
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
Customer Service: +39 011.23.39.810 - Export Dept. Phone: +39 011.24.00.250/256 -
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from date of manufacture. The material must be used according to the instructions provided and
for its intended use. Faults must not be caused by deterioration or accidents resulting from negligence, anomalous use or incorrect installation. In all cases, the warranty only includes replace-
ment of faulty products. No compensation for loss or damage may be claimed.
DS1054-014A
contact
closed
contact
open
4 pulses
Reply (2)
10 clicks
1 click
2 clicks
3 clicks
4 clicks
5 clicks
6 clicks
7 clicks
8 clicks
9 clicks
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
For technical information, go to www.yokis.com or call:
Fax: +39 011.24.00.296
Technical specifications:
Mains voltage:
Output contact:
Module consumption:
Sound level:
Operating temp.:
Relative humidity:
Dimensions:
Contact of a timer, twilight
sensor, or anemometer
time
time
Toward the MVR500E
driver wire
------ function configuration -------
Number of
Presses (1) Function
20
Contact behavior inversion
21
Lock configurations
23
Unlock configurations
25
Prepare to configure X
26
Prepare to configure Y
30
Full reset to default settings
(1) successive short presses on the temporary pushbutton connected to
the pushbutton terminal.
(2) confirmation reply by relay "clicks" after presses sequence.
(4) To configure X, first short press 25 times. To configure Y, first short
press 26 times.
P3
GB
230V~ +10% -15% - 50Hz
1A - 250VAC; max. 250VA
< 1W
< 60dB at 20 cm
from -20°C to +60°C
from 0 to 99%
48 x 32 x 20 mm [1.89 x 1.26 x 0.79"]
Coil
230V
50Hz
Contact
10A-250V~
Reply (2)
10 clicks
1 click
3 clicks
5 clicks
6 clicks
2 clicks