MA IN T EN ANCE
Depending on the water you use, minerals and sediment may collect in
the steamer and affect the free flow of steam. Limescale found in tap
water can also affect the performance of the steamer. To reduce this,
we recommend using demineralised or distilled water.
To keep the steamer optimal, maintain your steamer once a month. In
a commercial setting, maintain even more often. We advise you both
remove mineral deposits and descale.
To remove mineral deposits, please follow this procedure. Turn the unit
off and unplug from the power outlet. Remove the hose and telescopic
pole from the base. Wrap up the power cable to avoid it getting wet.
In a large sink or bath, unscrew the drainage value (on the side of the
machine, next to the wheel). Be prepared, water from the inside of
the machine will start to pour out, including any sediment or minerals.
Add water to the water tank and place on the machine so that there
is plenty of water flowing through the unit, flushing it of sediment and
minerals. Continue this process until the water runs clear and tighten
the drainage valve properly.
To descale your steamer, we advise using the descaling crystals that
are found inside the box of this steamer. Add a small amount of crystals
to the water tank (a pinch). After placing the water cap on the tank,
shake the solution and place on the unit. Turn the unit on and direct the
steam out of a window (or ideally do this outside). Leave steaming for
at least ten minutes. Replace the water in the water tank for fresh water
and leave to steam for another ten minutes at least. Repeat as desired.
Your steamer in now descaled.
Re-assemble the appliance and operate as usual.
There are two sachets inside your box for your first two descaling
sessions. Further sachets are available at www.fridja.com.
16
ENGLISH
f1000 FRIDJA PROFESSIONAL GARMENT STEAMER
T ROU BLE SHOOTIN G
Problem
Reason
Unit fails to steam,
Steamer is not
light does not turn on
plugged in
Unit fails to steam
There is substantial
mineral deposits
throughout the unit
Water storage tank
is empty
'Gurgling' sound from
Condensation
hose, steamer head or
within the hose
base unit
Steam is intermittent
Substantial mineral
deposits in the unit
Solution
Plug the unit into a
suitable power outlet and
turn on if applicable
Follow the remove
mineral deposits
procedure
Fill the water storage
tank
'Gurgling' is normal
during the steaming
process. If there is
excessive gurgling,
extend the hose to allow
excess water to drain
back into the water
storage tank
It is normal for the unit
to periodically stop
steaming for a few
seconds
However if this occurs
for longer periods, follow
the remove deposits
procedure