Uline H-8271 Guia De Inicio Rapido

Kit de servicio para sistema industrial de envoltura termoencogible
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

H-8271, H-8272
H-8273, H-8274
SERVICE KIT FOR INDUSTRIAL
SHRINK SYSTEM
TOOLS/SUPPLIES NEEDED
Flat Head Screwdriver
1.
Remove worn silicone rubber pad from metal channel.
2. Place new silicone rubber pad (A) inside metal
channel (B). (See Figure 1)
NOTE: Trim to fit.
B
Figure 1
3. Clean new silicone rubber pad with rubbing alcohol
and a clean cloth.
4. Apply the dark brown 10 mil Teflon Tape (C) to top of
silicone rubber pad (A). (See Figure 1)
CAUTION! Unplug shrink wrap system before
replacing nichrome wire.
1.
Locate and remove black plastic screw (G) on right
side of the sealing arm. Remove black plastic end
cap (H). Remove white plastic insulator sleeve (I).
(See Figure 2)
PAGE 1 OF 6
Phillips Head Screwdriver
TEFLON TAPE REPLACEMENT
C
A
NICHROME WIRE REPLACEMENT
1-800-295-5510
uline.com
Rubbing Alcohol
5. Remove worn tape from flexboard (D) on bottom of
sealing arm. (See Figure 2)
Shrink Wrap System Arm
D
NOTE: If there is a yellow or brown film residue
built up on the flexboard, it will need to be
scraped off before applying the new Teflon tape.
6. Apply light brown 3 mil Teflon tape to flexboard over
nichrome sealing wire (F).
7.
Extra pieces of Teflon tape have been included for
future use.
2. Locate the phenolic
assembly and remove
from arm slot by pulling
downward. (See Figure 3)
3. Remove the screw that
secures the wire to the
assembly. (See Figure 3)
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.
I
H
F
Figure 2
Figure 3
Screw
Phenolic
Assembly
0621 IH-8271
G
loading

Resumen de contenidos para Uline H-8271

  • Página 1 Para Español, vea páginas 3-4. Pour le français, consulter les pages 5-6. H-8271, H-8272 1-800-295-5510 H-8273, H-8274 uline.com SERVICE KIT FOR INDUSTRIAL SHRINK SYSTEM TOOLS/SUPPLIES NEEDED Flat Head Screwdriver Phillips Head Screwdriver Rubbing Alcohol TEFLON TAPE REPLACEMENT Remove worn silicone rubber pad from metal channel.
  • Página 2 Step 3 to secure the new wire. 6. Slide phenolic assembly back in place with flat side of insulator facing the arm. Replace insulator sleeve (I) and end cap (H) and tighten screw (G). 1-800-295-5510 uline.com PAGE 2 OF 6 0621 IH-8271...
  • Página 3: Kit De Servicio Para Sistema Industrial De Envoltura Termoencogible

    H-8271, H-8272 800-295-5510 H-8273, H-8274 uline.mx KIT DE SERVICIO PARA SISTEMA INDUSTRIAL DE ENVOLTURA TERMOENCOGIBLE HERRAMIENTAS/SUMINISTROS NECESARIOS Desarmador Plano Desarmador de Cruz Alcohol Medicinal REEMPLAZAR LA CINTA DE TEFLÓN 1. Quite la almohadilla de goma de silicona 5. Quite la cinta desgastada de la placa flexible (D) desgastada del canal de metal.
  • Página 4: Continuación De Reemplazar El Alambre De Nicromo

    Vuelva a colocar la funda aislante (I) y la tapa de extremo (H) y apriete el tornillo (G). 800-295-5510 uline.mx PAGE 4 OF 6 0621 IH-8271...
  • Página 5 H-8271, H-8272 1-800-295-5510 H-8273, H-8274 uline.ca ENSEMBLE DE SERVICE POUR SYSTÈME DE FILM RÉTRACTABLE INDUSTRIEL OUTILS/FOURNITURES NÉCESSAIRES Tournevis à tête plate Tournevis à tête cruciforme Alcool à friction REMPLACEMENT DU RUBAN ADHÉSIF EN TEFLON Retirez le tampon en caoutchouc de silicone usé de 5.
  • Página 6 6. Réinstallez l'ensemble phénolique de manière à ce que le côté plat de l'isolant soit orienté vers le bras. Remplacez le manchon isolant (I) et l'embout (H), puis serrez la vis (G). 1-800-295-5510 uline.ca PAGE 6 OF 6 0621 IH-8271...

Este manual también es adecuado para:

H-8272H-8273H-8274