Legend Brands Dri-Eaz LGR 6000Li Manual Del Propietário

Legend Brands Dri-Eaz LGR 6000Li Manual Del Propietário

Ocultar thumbs Ver también para Dri-Eaz LGR 6000Li:
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

LGR 6000Li Portable Dehumidifier
The Dri-Eaz
®
LGR 6000Li dehumidifier reduces humidity in enclosed environments by removing
water vapor from the air. The 6000Li is rugged, durable and highly portable, making it ideal for
water damage restoration, structural drying, construction, and other applications requiring
temporary, high-performance dehumidification.
R E A D A N D U N D E R S T A N D B E F O R E O P E R A T I N G
WARNING
SAFETY INSTRUCTIONS
WARNING! Do not alter or modify your dehumidifier
in any way. Use only replacement parts authorized
by Legend Brands, Inc., Modifications or use of
unapproved parts could create a hazard and will
void your warranty. Contact your authorized
distributor for assistance.
WARNING! Electric shock hazard, rotating fan, hot
surface hazards. Unplug unit before opening cover
for cleaning or servicing. Unit must be grounded.
CORRECT PLUG REMOVAL
Grasp IEC plug and pull straight out
IMPORTANT: Damage to IEC receptacle or
dehumidifier resulting from improper removal
of the power cord is not covered by warranty.
The IEC power cord is a wear item and is not
covered by warranty.
108259F #103614 (F600)
Owner's Manual
Model 103614 (F600)
Legend Brands, Inc.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932-3030 Fax: 360-757-7950 LegendBrandsRestoration.com
Patents: LBpatents.com
• Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
• Insert three-prong plug on power cord into a
matching electrically grounded outlet. Do not use
adapter. Never cut off third prong. Do not use an
extension cord.
• The unit must be operated on a 115V/60Hz circuit
protected by a Ground Fault Circuit Interrupter
(GFCI) device.
• Keep motor and wiring dry.
• Do not attempt to repair the unit. For Authorized
Service Centers, contact Dri-Eaz.
NOTICE: Do not use in environments where
corrosive chemicals are present, such as chlorine.
BEFORE YOU BEGIN
Warranty registration
Visit
Warranty.LegendBrandsRestoration.com
your purchase. Registration allows us to better assist
you with using, maintaining or servicing your equipment
and to contact you in case we have important safety
information concerning your Dri-Eaz product. If you
determine service is required, have your equipment
model, serial number and original proof of purchase
available and call your distributor for assistance with
obtaining a return material authorization (RMA).
CONTROLS AND OPERATING
INSTRUCTIONS
Set unit upright
NOTICE: Transporting or storing the unit in a
horizontal position is not recommended. When the
machine is placed in a horizontal position, the oil
from the compressor can flow into the refrigerant
coils and reduce the ability of the dehumidifier to
function and possibly damage the unit. If the unit
has been placed in a horizontal position, set it
1
to register
Legend Brands, Inc.
Tabla de contenido
loading

Resumen de contenidos para Legend Brands Dri-Eaz LGR 6000Li

  • Página 7: Instrucciones De Seguridad

    Nunca corte la tercera pata. No use un deshumidificador de ninguna forma. Use solo piezas cable de extensión. de repuesto autorizadas por Legend Brands, Inc., • La unidad debe utilizarse en un circuito de Las modificaciones o el uso de piezas no aprobadas 115 V/60 Hz protegido por un dispositivo de podrían crear un peligro y anularán su garantía.
  • Página 8: Coloque La Unidad En Posición Vertical

    15 amperios. Quite el cable de la bandeja de Salida de aire almacenamiento y desenróllelo. Siempre (deshumidificado) tras enchufe bien el cable en la unidad primero y el proceso. luego enchufe el otro extremo en un tomacorriente adecuado. 108259F #103614 (F600) Legend Brands, Inc.
  • Página 9: Cómo Usar El Panel De Control

    Presione PURGA para vaciar el tanque de condensado Presione ENCENDER/APAGAR para apagar la unidad Para obtener instrucciones detalladas sobre el panel de control, visite la página del producto del Controlador i-Series en Controller.LegendBrandsRestoration.com. 108259F #103614 (F600) Legend Brands, Inc.
  • Página 10: Errores Y Advertencias

    AVISO: Para que el tanque de condensado esté vaciado por completo tras la purga, vele por colocar la unidad en posición vertical sobre una superficie horizontal. 108259F #103614 (F600) Legend Brands, Inc.
  • Página 11: Transporte Y Almacenamiento

    (frío) sin la cubierta del frente. Si observa una Taladro inalámbrico, cuchillo pequeño, pinzas de cantidad excesiva de polvo y suciedad, aspire bien o punta pequeña, solución limpiadora de bobinas, limpie con un limpiador para bobinas. solución limpiadora de carcasas rotomoldeadas. 108259F #103614 (F600) Legend Brands, Inc.
  • Página 12: Resolución De Problemas

    25 pies | 7,6 m Construcción Carcasa rotomoldeada Seguridad Certificación ETL CSA 22.2 n.º 92 Las especificaciones técnicas pueden cambiar sin previo aviso. Algunos valores pueden ser aproximados. *La velocidad del ventilador varía automáticamente para un rendimiento optimizado. 108259F #103614 (F600) Legend Brands, Inc.

Este manual también es adecuado para:

F600

Tabla de contenido