Contains one or more (extremely/highly)
flammable components.
• Ensure you have fully read and understood the instructions in this
document before you install or use the product. Keep the
packaging and this document for future reference.
• Only use the product as described in this manual.
• This product can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the product in a safe
way and understand the hazards involved. Children shall not play
with the product. Cleaning and user maintenance shall not be
done by children without supervision.
• Close supervision is necessary when the product is used by or near
children, animals or infirm persons. Do not allow children to play
with it or touch it.
• Keep the product out of reach from children.
• Do not use a damaged or defective product, but return it for repair
or replacement.
• Do not expose the product to water, rain, moisture or high
humidity.
• If the product is immersed in water, do not touch the product or
the water.
• Shut off the main power grid and carefully remove the plug from
the power outlet.
• After the product has been immersed or covered in water or other
liquids, do not use the product again.
• Keep the product away from heat sources. Do not place the
product on hot surfaces or near open flames.
• Do not use the product near explosive or flammable materials.
• Do not insert any objects into the product.
• Do not obstruct or cover the product's air inlet or outlet grid.
• The appliance shall be installed in accordance with national wiring.
• Always disconnect the product from the power outlet when
cleaning or moving the product.
• Do not pull the power cable to move the product.
• Unplug the product from the power source and other equipment
if problems occur.
• Do not unplug the product by pulling on the cable. Always grasp
the plug and pull.
• Switch off the main power switch before unplugging the power
cord.
• Do not use the product when the cord or plug is damaged.
• Make sure that the electrical supply in your area matches a voltage
of 220 – 240 VAC and a frequency of 50 Hz.
• Connect to a grounded socket only.
• If necessary, use an earthed extension cable of a suitable diameter.
• Fully extend the power cord and make sure the power cord does
not contact the product.
• When using an extension cord, use one which is as short as
possible and fully extended.
• Do not use external timers or remote control systems to switch the
product on or off.
• Ensure people do not trip over the cord.
• Make sure that the power cable cannot become entangled and
does not hang over the edge of a worktop.
• Do not leave the product unattended when switched on.
• R290 is a refrigerant gas that complies with the European
directives on the environment.
• Be aware that refrigerants can be odorless.
• Place the product in an area without any continuous sources of
ignition (for example: open flames, gas or electrical appliances in
operation).
• Only install, operate and store the product in a room with a floor
area above 11 m2.
• Only store the product in a well-ventilated area.
• Store the product in such a way as to prevent mechanical failure.
• When the product is installed, operated or stored in a
non-ventilated area, make sure the room is designed to prevent
the accumulation of refrigerant leaks resulting in a risk of fire or
explosion due to ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
• Only persons with a current valid certificate from an industry-
accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry recognized assessment specification, can work on or
break into a refrigerant circuit.
• Servicing can only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel can only be carried out under
the supervision of the person competent in the use of flammable
refrigerants.
• When defrosting and cleaning the product, do not use any means
other than those recommended by the manufacturing company.
• Do not puncture or heat any part of the refrigerant circuit.
• This product may only be serviced by a qualified technician for
maintenance to reduce the risk of electric shock.
Installing the product
-
Place the product on a stable and flat surface.
-
Leave a minimum of 0.5 m space around the air inlet and outlet
to allow a good circulation of airflow.
-
Only move the product in an upright position.
-
If the product has been tilted, allow it to stand upright for 2
hours before plugging it in.
Assembling the exhaust (image B)
-
Only use the provided exhaust hose.
-
Do not block the exhaust hose, this may cause overheating.
1. Assemble the window kit A
w
2. Install A
in the window opening.
3. Tighten A
y
.
4. Assemble the exhaust hose A
exhaust hose connector A
q
5. Connect A
the air outlet A
8
6. Extend A
up to 1500 mm.
-
Do not twist the exhaust hose.
-
Ensure that the exhaust hose does not kink.
7. Snap A
9
into A
w
and fasten with the exhaust nozzle screw
u
.
A
4
Place the product on a flat and dry surface.
Assembling the continuous drainage (optional)
1. Open the continuous drainage outlet A
2
2. Connect A
to a water container or drainage system (not
included).
Using the control panel (image C)
7
Switch the product on or off.
C
6
Switch between cooling, dehumidifying and fan mode.
C
2
Switch between high, middle and low fan speed. In
C
dehumidifying mode, pressing C
to low speed.
1
1
Press C
and use C
C
of cooling.
The timer can be set to a maximum of 24 hours.
4
Display
C
5
w
y
with the fasteners A
.
8
9
, the exhaust nozzle A
q
.
3
.
2
.
2
switches the fan
3
5
and C
to set the duration
and the