Trouble Shooting
Fault
Display does not come on and
dispenser does not work
Display shows Error E1
Display shows Error E2
Display shows Error E3
Display shows Error E4
Display shows Error E5
E5 Malfunction Process
1. Turn off the power and remove the plug.
2. Open the towel-receiving plate
3. Unscrew and open the front panel
4. Push the red button to set the knife to the open position
5. Lift the towel pressing cover and pull out the towel
6. Move the cylinder in upwards direction to release any towel rolls jammed inside.
Note: Do not move cylinder in a downwards direction
7. Replace the Front panel
8. Turn on the Power
9. Set the output towel number to 01, and push the start button. If no warning message appears the
machine should run normally.
If error E5 cannot be cleared by following the E5 malfunction processing step please call your Buffalo agent
or qualified engineer.
Technical Specification
Code
Voltage
GD266
220-240v 50Hz
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 3 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
• Live wire (coloured brown) to terminal marked L
• Neutral wire (coloured blue) to terminal marked N
• Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Telephone Helpline: 0845 146 2887 (United Kingdom)
Probable Cause
Power is not switched at socket
Plug fuse has failed
Power Cable is damaged
Water low or water tank not in
place
Towel low
Water and towel low
Towel seizure at outlet
Machine Fault
Power
Current
400w
1.8A
Action Required
Turn Power on at socket
Change Fuse
Call BUFFALO dealer for repair
service
Refill water or replace water tank
Refill towel roll
Refill water or towel roll
Remove towel from outlet
Follow E5 Malfunction Process
Dimensions
(H x W x D mm)
375 x 250 x 485
Weight
8kg