36" GAS RANGE INSTALLATION INSTRUCTIONS
E. Convert Oven Burner Orifice
1. Remove storage drawer if equipped or lower panel
to gain access to oven burner spuds.
2. Remove oven bottom and oven burner baffle
located on top of burner. To remove oven bottom,
pull up at rear, disengaged front of bottom from
oven front frame, and pull the oven bottom straight
out of the oven. Remove burner baffle so that the
burner flame can be observed.
3. Using ½" wrench, turn down the adjustable spud
which injects gas into the oven burner, until snug
against the LP metering pin. This will be
approximately 2 ½ turns. Do Not Overtighten.
4. Push the BAKE TEMP button, then SET the
temperature to 300°F. Wait until burner starts to
cycle. To determine if the oven burner flame is
proper, observe the flame. It should be steady with
approximately 1" blue cones and no yellow or
orange flame tips.
Figure 14
5. If adjustment to the air shutter is necessary, locate
oven burner air shutter, loosen shutter set screw and
adjust to obtain optimum flame (figure 14). This
will normally be completely open for LP gas.
Tighten shutter set screw.
F. Convert Waist High Broiler Burner Orifice
Flame
(Self-Clean Models Only)
Figure 15
Air Shutter
Spud
Pin
Nat.
L.P.
6
1. Open oven door.
2. Locate broiler burner spud and turn down
approximately 2 ½ turns so that spud is snug against
LP metering pin. Do Not Overtighten.
3. To determine if burner flame is proper, push the
BROIL button, then turn the SET knob to the LO
setting, and observe broiler flame. It should be
steady and sharp with approximately 1" blue cones
and no yellow or orange flame tips.
4. If adjustment to the air shutter is necessary, locate
oven burner air shutter, loosen shutter set screw and
adjust to obtain optimum flame (figure 14). This
will normally be completely open for LP gas.
Tighten shutter set screw.
6. Connect Electricity to Gas Range
Electrical Requirements
120 volt, 60 Hertz, individual, properly grounded and
polarized branch circuit protected by a 15 amp. circuit
breaker or time delay fuse.
Extension Cord Cautions:
Because of potential safety hazards under certain
conditions we strongly recommend against the use of
any extension cord. However, if you still select to use an
extension cord, it is absolutely necessary that it be a UL
listed 3-Wire grounding type appliance extension cord
and that the current carrying rating of the cord in
amperes be equivalent to or greater than the branch
circuit rating. Such extension cords are obtainable
through your local service organization.
Grounding Instructions
IMPORTANT Please read carefully.
For personal safety, this appliance must be properly
grounded.
The power cord of this appliance is equipped with a 3-
prong (grounding) plug which mates with a standard 3-
prong grounding wall receptacle (see Figure 8) to
minimize the possibility of electric shock hazard from the
appliance.
The wall receptacle and circuit should be checked by a
qualified electrician to make sure the receptacle is
properly grounded.