Enlaces rápidos

FCC/IC - EN
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standards.
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different to which the receiver is
connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to the
antenna or the device is permitted. Any change to the antenna or the device could result in the
device exceeding the RF exposure requirements and void user's authority to operate the device.
FCC/IC - FR
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils exempts
de licence d'Industrie Canada. Son utilisation est sujette aux deux conditions suivantes (1) cet
appareil ne doit pas occasionner de brouillage préjudiciable et (2) cet appareil doit accepter
toutes les interférences reçues, notamment les interférences qui peuvent provoquer un
fonctionnement non désiré.
REMARQUE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de
ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à utiliser cet
appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont été
définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en milieu
résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et, s'il
n'est pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage
préjudiciable aux communications radio. Il n'existe toutefois aucune garantie que des
interférences ne se produiront pas dans une installation donnée. Si cet appareil occasionne un
brouillage préjudiciable à la réception radiophonique ou télévisuelle, il suffit d'allumer et
d'éteindre l'appareil pour déterminer sa responsabilité. Nous encourageons l'utilisateur à
essayer de corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Pour obtenir de l'aide, consulter le revendeur ou un technicien spécialisé en postes radio ou
téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant
l'exposition aux RF, aucune modification apportée à l'antenne ou au dispositif n'est autorisée.
Toute modification apportée à l'antenne ou au dispositif pourrait faire en sorte que le dispositif
dépasse les exigences d'exposition aux RF et pourrait annuler le droit de l'utilisateur à utiliser ce
dispositif.
FCC/IC - ES
Este dispositivo cumple con las especificaciones del apartado 15 de las normas de la FCC y con
las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria de Canadá
aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las siguientes dos
condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2) este
dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar un
funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio o TV
ocasionada por modificaciones no autorizadas efectuadas a este equipo. Estas modificaciones
podrían anular la autoridad del usuario para utilizar este equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para dispositivos digitales de Clase B,
de conformidad con el apartado 15 de la normativa de la FCC. Estos límites están diseñados para
proveer protección razonable contra interferencias perjudiciales en instalaciones residenciales.
Este equipo genera, usa y puede irradiar energía de radiofrecuencias y, si no se instala y usa
según las instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No
obstante, no hay garantías de que no ocurrirá interferencia en una instalación en particular. Si
este equipo provoca interferencia perjudicial a la recepción de radio o televisión, lo que puede
determinarse encendiendo y apagándolo, se recomienda que el usuario intente corregir la
interferencia aplicando una o más de las siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que el receptor
está conectado.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para solicitar
asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier cambio
a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de exposición
de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
Responsible Party - US Contact Information | Parte responsable - Información de contacto de los
Estados Unidos | Partie responsable - Coordonnées des États-Unis
FCC — U2ZZW4008 | IC: 6924A-ZW4008
Resideo Technologies, Inc. | Model: ZW4008/39455
2 Corporate Center Dr. Suite 100, P.O. Box 9040, Melville, NY 11747 | 1-800-645-7492
CAN ICES-3(B)/NMB-3(B)
All brand names shown
Tous les noms de marque illustrés
Todos los nombres de marca
are trademarks of their
sont des marques de commerce
que aparecen son marcas
respective owners.
de leurs propriétaires respectifs.
comerciales pertenecientes a
sus respectivos propietarios.
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
39455 | ZW4008 | 03/27/20 v4
Resideo Technologies, Inc.
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
www.security.honeywellhome.com | 1-800-645-7492
1
TOOLS
IMPORTANT!
The fixture controlled by the Z-Wave in-wall smart switch must not exceed 960W incandescent;
1800W (15A) resistive or 1/2HP motor. The switch is designed only for use with permanently
installed fixtures.
2
FEATURES
• Turn ON/OFF manually or remotely via the Z-Wave controller
• Can be added in multiple groups and scenes
• May be used in single-pole installation or with up to two Resideo add-on
switches (model 39457) in 3-way or 4-way wiring configurations
• Compatible with all CFL/LED and incandescent bulbs
• Interchangeable paddle switch — white & light almond paddle in package
• Uses a standard, rocker-style wallplate for single-gang installations
(wallplate not included)
• Blue LED indicates switch location in a dark room
• Z-Wave certified for simple pairing and integrated home automation
• Screw terminal installation — requires wiring connections for line (hot),
load, neutral and ground. Traveler wire required for 3-way or 4-way
installation
A
B
D
F
G
E
C
A.
F.
Ground (Green/Bare)
Top rocker — Press &
release to turn switch ON
B.
Line or Load (Black)
G.
Bottom rocker — Press &
C.
Line or Load (Black)
release to turn switch OFF
D.
Traveler (Red/Other)
E.
Neutral (White)
SMART SWITCH
IN-WALL
INTERRUPTEUR INTELLIGENT
MURAL
INTERRUPTOR INTELIGENTE
DE PARED
Z5SWITCH
Z-W
® C
W
l
C
ave
ertified
ireless
ighting
ontrol
Z-W
® C
i
i
C
ave
ontrol de
luminaCión
nalámbriCo CertifiCado
ontrol
Z-W
®
inalámbriCo para iluminaCión CertifiCado por
ave
3
INSTALLATION
1
1
2
3
out to light
(
)
load
B
D
C
E
A
5
7
from breaker box
out to light
(load)
A
B
D
E
C
8
9
10 11
from breaker box
13
14
SUPPORT
SOUTIEN
APOYO
https://mywebtech.honeywellhome.com/
U.S. WARRANTY
U.S. GARANTIE
GARANTÍA DE U.S.
https://www.security.honeywellhome.com/
hsc/resources/wa/index.html
WARNING
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES
CONTROL DE APARATOS
CAUTION:
PRECAUCIÓN:
• DO NOT EXCEED RATINGS
• NO SUPERAR LOS VALORES NOMINALES
ELÉCTRICOS
• DO NOT USE TO CONTROL ANY DEVICE WHERE
UNINTENDED OPERATION COULD CAUSE
• NO USAR PARA CONTROLAR DISPOSITIVOS EN
UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP,
LOS QUE EL FUNCIONAMIENTO NO
ETC.)
INTENCIONADO PODRÍA PROVOCAR
SITUACIONES PELIGROSAS (LÁMPARAS DE
• FOR INDOOR USE ONLY
CALEFACCIÓN, LÁMPARAS SOLARES, ETC.)
AVERTISSEMENT
• PARA USO EN INTERIORES EXCLUSIVAMENTE
RISQUE D'INCENDIE
NOT FOR USE WITH MEDICAL OR
RISQUE DE CHOC ÉLECTRIQUE
LIFE-SUPPORT EQUIPMENT
RISQUE DE BRÛLURES
Z-WAVE ENABLED DEVICES SHOULD NEVER BE
COMMANDE DES APPAREILS
USED TO SUPPLY POWER TO OR CONTROL THE
ATTENTION :
ON/OFF STATUS OF MEDICAL OR LIFE-SUPPORT
EQUIPMENT.
• NE PAS DÉPASSER LES CARACTÉRISTIQUES
NOMINALES
NE PAS UTILISER AVEC UN ÉQUIPEMENT
• NE PAS UTILISER POUR COMMANDER DES
MÉDICAL OU DE SURVIE
APPAREILS POUR LESQUELS UN
LES DISPOSITIFS COMPATIBLES AVEC LA
FONCTIONNEMENT IMPRÉVU POURRAIT
TECHNOLOGIE Z-WAVE NE DEVRAIENT JAMAIS
ENTRAÎNER DES CONDITIONS DANGEREUSES
ÊTRE UTILISÉS POUR ALIMENTER OU
(LAMPE INFRAROUGE, LAMPE SOLAIRE, ETC.)
COMMANDER LA MISE EN MARCHE OU L'ARRÊT
DE L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
• POUR UTILISATION INTÉRIEURE UNIQUEMENT
SE PROHÍBE SU EMPLEO EN EQUIPO MÉDICO
O EQUIPO PARA EL MANTENIMIENTO DE LAS
FUNCIONES VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN
USAR PARA SUMINISTRAR ENERGÍA ELÉCTRICA,
NI PARA CONTROLAR EL ESTADO DE ENCENDIDO
O APAGADO DEL EQUIPO MÉDICO Y/O EL EQUIPO
PARA EL MANTENIMIENTO DE FUNCIONES
VITALES.
ZW4008
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel.
All wiring connections must be made with the POWER OFF to avoid personal injury or damage to
the switch. This device is intended for installation in accordance with the National Electric
Code and local regulations in the United States or the Canadian Electrical Code and local
regulations in Canada. If you are unsure or uncomfortable about performing this installation,
consult a qualified electrician.
MULTI-SWITCH WIRING
The Resideo add-on switch (model 39457) is required for multi-switch 3-way
or 4-way installations. Connecting the traveler terminal of this switch to a
standard, non-Resideo switch will cause damage or result in improper
function. If this switch is part of a 3-way or 4-way multi-switch installation,
do not connect the traveler wire or apply power until Resideo add-on switches
are correctly installed. For more information on 3-way or 4-way installations,
view the manual or quick-start guide with the Resideo add-on switch.
SINGLE-SWITCH WIRING
Before installation, you may wish to change the paddle color to match your
wallplate or décor. Please proceed to Section 5.
1.
Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2.
Remove wallplate.
3.
Remove the switch mounting screws.
4.
Carefully remove the switch from the switch box. DO NOT disconnect
the wires.
5.
There are up to five screw terminals on the switch.
These are marked:
A. GROUND — Green/Bare
B. LINE or LOAD — Black (connected to power or lighting)
C. LINE or LOAD — Black (connected to power or lighting)
D. TRAVELER — Red/Other (only in 3-way installations)
E. NEUTRAL — White
Match these screw terminals to the wires connected to the existing
switch.
6.
Disconnect the wires from the existing switch. Label wires according
to the previous terminal connection.
OBSERVE IMPORTANT WIRING INFORMATION
IMPORTANT! This switch is rated for and intended to only be used with copper
wire.
WIRE GAUGE REQUIREMENTS
Use 14 AWG or larger wires suitable for at least 80°C for supplying line (hot),
load, neutral, ground and traveler connections.
WIRE STRIP LENGTH
7.
For attachment using the enclosure's holes, strip insulation 5/8in.
(16mm).
UL specifies the tightening torque for the screws is 14Kgf-cm
(12lbf-in).
8.
Connect the green or bare copper ground wire to the GROUND terminal.
9.
Connect the black wire from the light to either LINE/LOAD terminal.
10.
Connect the black wire from the electrical service panel (hot) to the
other LINE/LOAD terminal.
11.
Connect the white wire to the NEUTRAL terminal (use a jumper wire
if needed).
NOTE: The traveler terminal is only used for 3-way or 4-way wiring and
should remain unconnected if the switch is being installed in a
single-pole installation (one switch & one load).
12.
Insert switch into the switch box being careful not to pinch or crush
wires.
13.
Switch must be independently mounted (vertical position only).
14.
Secure the switch to the box using the supplied screws.
15.
Mount the wallplate.
16.
Reapply power to the circuit at fuse box or circuit breaker and test
the system.
BASIC OPERATION
The connected light can be turned ON/OFF in two ways:
• Manually from the front panel of the in-wall switch.
• Remotely with a Z-Wave controller.
MANUAL CONTROL
The front panel rocker switch allows the user to turn ON/OFF the
connected fixture.
• To turn the connected fixture ON, press and release the top of the rocker.
• To turn the connected fixture OFF, press and release the bottom of the
rocker.
CYCLE LED INDICATOR LIGHT
The LED below the switch acts as a guide light or status indicator.
How to cycle through options: Press up three times and down once quickly.
1.
LED is ON when the load is OFF (guide light in the dark) (default)
2.
LED is ON when the load is ON (indicates the switch is ON)
3.
LED is always OFF
4.
LED is always ON (illuminates switch in the dark)
PARAMETERS
This Z-Wave smart switch has advanced features that allow you to customize your experience
— these features can only be adjusted by a Z-Wave enabled controller that supports the Z-Wave
configuration command class.
NUMBER
SIZE
WebTech
3
1
4
1
Warranty/Garantie/
19
1
Garantía
ADVERTENCIA
SPECIFICATIONS
ZW4008
Power: 120VAC, 60Hz
Signal (frequency): 908.4/916MHz
Maximum loads: 960W, incandescent, 1/2HP motor or 1800W (15A) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave
receiver module
Operating temperature range: 32-104 °F (0-40 °C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c
action, pollution degree (2), impulse voltage (2500V), software class A
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4008
Alimentation : 120VCA, 60Hz
Signal (fréquence) : 908.4/916MHz
Charges maximales : 960W incandescent, moteur de 1/2HP ou résistance de 1800W (15A)
Portée : Distance à vue maximale de 150pi (45.7m) entre la télécommande et le module de
réception Z-Wave le plus proche
Plage de températures de fonctionnement : De 32 à 104 °F (de 0 à 40 °C)
Boîtier de type 1, monté indépendamment (position verticale seulement), intervention de type
1.c commande de fonctionnement, degré de pollution (2), tension de choc de (2500V), logiciel de
classe A
Utilisation intérieure uniquement
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de
changements sans préavis
ESPECIFICACIONES
ZW4008
Alimentación: 120VCA, 60Hz
Señal (frecuencia): 908.4/916MHz
Cargas máximas: 960W para dispositivos incandescentes, motor de 1/2HP o 1800W (15A) de
carga resistiva
Alcance: Hasta 150 pies (45.7m), sin obstrucciones, entre el controlador inalámbrico y el módulo
receptor Z-Wave más cercano
Rango de temperatura de funcionamiento: 32-104 °F (0-40 °C)
Recinto de tipo 1, independientemente montado (solo en posición vertical), control de operación:
acción tipo 1.c , grado de contaminación (2), voltaje de impulso (2500V), software de clase A
Para uso en interiores exclusivamente
Las especificaciones están sujetas a cambios sin previo aviso por las constantes mejoras a que
se someten los productos
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other applications. All nonbattery-operated nodes
within the network will act as repeaters regardless of vendor to increase reliability of the
network.
INTEROPÉRABILITÉ ENTRE LES DISPOSITIFS Z-WAVE
Ce produit peut être utilisé dans un réseau Z-Wave avec d'autres appareils certifiés Z-Wave
produits par d'autres fabricants et d'autres applications. Tous les nœuds fonctionnant sans pile
au sein du réseau joueront le rôle de répétiteurs, quel que soit le fournisseur, afin de rehausser la
fiabilité du réseau.
INTEROPERABILIDAD Z-WAVE
Este producto se puede incluir y puede funcionar en cualquier red Z-Wave con dispositivos de
otros fabricantes y otras aplicaciones que cuenten con la homologación Z-Wave. Todos los nodos
que formen parte de la red y que funcionen sin pilas actuarán de repetidores
independientemente del proveedor con el fin de aumentar la fiabilidad de la red.
4
CONNECTION
CONNECTING YOUR DEVICE TO A Z-WAVE NETWORK
1.
Follow the instructions for your Z-Wave certified controller to add a
device to the Z-Wave network.
2.
Once the controller is ready to add your device, press and release the top
or bottom of the smart switch (rocker) to add it in the network.
If prompted by the controller to enter the S2 security code, refer to the
QR code/security number on the back of the box, or the QR code label on
the product.
DSK :
XXXXX
-12565-22671
-26939-47599
-19612-25872
-47752
You have complete control to turn your fixture ON/OFF according to groups,
scenes, schedules and interactive automations programmed by
your controller.
If your Z-Wave certified controller features remote access, you can control
your fixture from your mobile devices.
REMOVING AND RESETTING THE DEVICE
1.
Follow the instructions for your Z-Wave certified controller to remove a
device from the Z-Wave network.
2.
Once the controller is ready to remove your device, press and release
the top or bottom of the smart switch (rocker) to remove it from the
network.
RETURNING SWITCH TO FACTORY DEFAULTS
Quickly press ON (top) button three times, then, immediately press the OFF
(bottom) button three times. The LED indicator will flash ON/OFF five times
when completed successfully.
NOTE: This should only be used in the event your network's primary controller
is missing or otherwise inoperable.
5
CUSTOMIZATION
CHANGING PADDLE COLOR
This step is optional. Before installation, you may want to change the color of
the paddle to match your wallplate or décor.
1.
Lift the air gap tab at the base of the paddle.
2.
Push side tabs in on one side and then the other to release paddle. Lift
the cover up and off.
3.
Simply put the new paddle onto the switch by inserting the air gap and
side tabs and snapping securely into place.
Once this step is complete, please return to section 3.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Binary Switch Report
• Association Group 2 supports Basic Set and is controlled by pressing
the ON or OFF button with the local load
• Association Group 3 supports Basic Set and is controlled by double
pressing the ON or OFF button
• Each Association Group supports 5 total nodes
DEFINITION
VALUE
Invert/disable LED
0 - LED ON/device OFF
(Adjusts when the indicator
1 - LED ON/device ON
LED is turned ON, OFF or
2 - Disable LED
disables it entirely)
0 (Default) - Default
Invert switch
(Top ON/bottom OFF)
(In case switch is
1 - Invert switch
installed upside down)
(Top OFF/bottom ON)
0 (Default) = Press any
button on the switch
Alternate exclusion
1 = Press two times
ON button and two
times OFF button
2
1
loading

Resumen de contenidos para resideo Z5SWITCH

  • Página 1 Shut off power to the circuit at circuit breaker or fuse box. device to the Z-Wave network. • May be used in single-pole installation or with up to two Resideo add-on IMPORTANT! Verify power is OFF to switch box before continuing.
  • Página 2 Le luminaire branché à l’interrupteur intelligent à montage mural Z-Wave ne doit pas dépasser de cet interrupteur à un interrupteur standard qui n’est pas de marque Resideo une résistance de 960W (lampe à incandescence), 1800W (lampe 15A) ou avoir un moteur de entraînera des dommages ou altérera son fonctionnement.

Este manual también es adecuado para:

Zw4008