Max. working area
Air flow
Dehumidifying at 20˚C and 70% r.h.
Dehumidifying at 35˚C and 80% r.h.
Power at 35˚C and 80% r.h.
Tank volume
Cooling medium, freon-free
Dimensions in mm., L x B x H
Weight
Noise level in decibels
PROBLEM
SOLUTION
Dehumidifier does not start
-
-
Does not dehumidify
-
-
-
-
High noise level
-
-
Ice formation on cooling coils
-
-
No water is drained from the
-
machine
-
-
"FULL" Tank is full
-
"Lo t" Environment temperature
-
too low . Defrost cycle is not able
-
to melt the ice in the battery
"LoPt"
-
Possible lack of gas in the circuit.
"Hi t"
-
Combination of temperature and
humidity is too high.
"Prob"
-
"Pro1" "Pro2" "Pro 3"
-
"PunP"
-
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
03

TECHNICAL DATA

TrOubLE SHOOTING
Check that the unit is connected to electricity and that no fuse has blown.
Check that the hygrostat is working. The dehumidifier should start when the hygrostat is in maximum position.
Check that the fan is spinning
Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean.
Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehumidifying cycle, when the compression stops.
Wait initially for about 35 minutes.
Check that a thick coating of ice has not formed on the cooling coils.
Increase distance between dehumidifier and surrounding surfaces.
Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils.
Remove air filter and check that no dust or fluff is obstructing passage of air through the machine.
Timer which controls defrosting may be broken, in which case compression will not stop regularly.
Check for obstruction to the drip-tray.
Unit under alarm.
When the red light is lit, the unit stops.
Empty the tank (note: only for models equipped with a water tank).
Set the dehumidifier above 10˚C
Switch the dehumidifier off and unplug it
The alarm automatically resets after 210 sec. If the alarm doesn't reset, press SET HOURS+ for 10 seconds. If the problem occurs again, call for service.
The alarm resets automatically when the temperature drops.
Malfunction humidistat. In any case, the machine continues to operate. Contact service to replace humidistat.
Malfunction of one of the three temperature probes. The dehumidifier goes into stand-by mode. Contact service to replace the probes.
The internal alarm of the pump is ON (for machines with pump). The alarm resets when the pump switch is closed.
WPF52
380 m
(24m
swimming pool surface)
2
2
600 m
/hour
3
26 l/day
58 l/day
0.95 kW/hour
N/A
410A
1008 x 211 x 602
48 kg
49 dB
Wood
leadi
Wood's
been kn
many y
the mo
dehum
good ev
humidi
good re
damp s
summe
for dryi
and lau
on ener
dehum
effectiv
The am
dehum
temper
placem
may als
the deh
relative
the extr
air by th
Therefo
for use
+35˚C. W
operati
use ove
Wood's
compre
other co
sa
Tabla de contenido

Solución de problemas

loading

Tabla de contenido