Apex Cleco mPro400GCD-M Descripción Del Hardware página 11

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Connectors – Internal power supply
Example:
Signal X9
Pin
I/O
12
11
10
Output
9
Output
8
Output
7
Output
6
Input
5
Input
4
Input
3
Input
2
1
Inputs
Internal 24 V power supply for the controller.
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
Pin 11 and 23 must be connected to Pin 12 or 24 with
jumpers.
Connectors – external power supply
Example:
Signal X9
Pin
I/O
12
11
10
Output
9
Output
8
Output
7
Output
6
Input
5
Input
4
Input
3
Input
2
1
+ -
Inputs
External 24 V power supply for the controller.
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
The GND for the external 24 V power supply must be
used as the return line for Pin 11 and 23.
Apex Tool Group
Name
Supply GND Int.
Supply GND I/O
O3
O2
O1
O0
I3
I2
I1
I0
Supply +24 V O
Supply +24 V Int.
Outputs
Name
Supply GND Int.
Supply GND I/O
O3
O2
O1
O0 (linking OK), e.g.
I3 (tool start), e.g.
I2
I1
I0
Supply +24 V O
Supply +24 V Int.
Outputs
P2309HW | 2018-09
Signal X10
Pin
I/O
Name
24
Supply GND Int.
23
Supply GND I/O
22
Output
O7
21
Output
O6
20
Output
O5
19
Output
O4
18
Input
I7
17
Input
I6
16
Input
I5
15
Input
I4
14
Supply +24 V O
13
Supply +24 V Int.
Internal 24 V power supply for the controller
Pin 2 and 14 (common output) are the voltage source
for the inputs.
Pin 2 and 14 must be connected to Pin 1 or 13
Signal X10
Pin
I/O
Name
24
Supply GND Int.
23
Supply GND I/O
22
Output
O3
21
Output
O2
20
Output
O1
19
Output
O0 (linking OK), e.g.
18
Input
I3 (tool start), e.g.
17
Input
I2
16
Input
I1
15
Input
I0
14
Supply +24 V O
13
Supply +24 V Int.
External 24 V power supply for the controller.
Pin 2 and 14 (common output) are the voltage source
for the inputs.
Pin 2 and 14 must be connected to the external 24 V
power supply.
1
EN
11
Tabla de contenido
loading

Este manual también es adecuado para:

Cleco mpro400gcd-p

Tabla de contenido