Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Issued / Herausgegeben / Publicado / Pubblicato
Instruction Leaflet
Bedienungsanleitung
Hojas de instrucciones
Foglio d'instruzioni
Figures / Abbildung / Figura
1
21.5
21.5
21.5
21.5
A. 7¯ input port
B. 4 high mounting bushings
C. Pin DimÕs 0.5 x 0.4mm
D. Style 3
E. Black finish steel lockring
F. Terminals
1. Vs (+)
2. Output (A)
3. Ground (-)
4. Output (B)
A. Puerto de entrada 7¯
B. 4 manguitos de montaje en
alto
C. Pin 0,5 x 0,4mm DIN
D. Estilo 3
E. Anillo de cierre de acero en
acabado negro
F. Terminales
1. Vs (+)
2. Salida (A)
3. Tierra (-)
4. Salida (B)
A
B
C
7
D
E
F
14.7
A. 7¯ Eingangsanschlu§
B. 4 hohe MontagehŸlsen
C. Stifte 0,5 x 0,4mm
D. Style 3
E. BrŸnierter Verschlu§ring
F. Klemmen
1. Vs (+)
2. Ausgang (A)
3. Erde (-)
4. Ausgang (B)
A. Porta dÕingresso ¯7
B. 4 boccole di montaggio alto
C. Din piedini 0.5 x 0.4mm
D. Stile 3
E. Anello di tenuta in finitura nera
F. Terminali
1. Vs (+)
2. Uscita (A)
3. Massa (-)
4. Uscita (B)
Low Pressure Transducers
Niederdruck-Meßumformer
Transductores de Baja Presión
Trasduttori di bassa pressione
2
V s
Voltage excitation
Excitaci—n de tensi—n
General
170PC pressure sensors are four-active-element piezoresistive
bridges.
When pressure is applied, a differential output voltage,
proportional to that pressure, is produced.
Gauge pressure sensors measure applied pressure with respect to
ambient pressure. When applied pressure increases, the differential
voltage between pins 2 and 4 increases (voltage at pin 2, with respect
to ground, increases and voltage at pin 4 decreases). As pressure
decreases, differential voltage between 2 and 4 decreases.
Differential sensors provide a differential voltage proportional to the
pressure differential between ports P2 and P1. As P2-P1 increases,
differential voltage increases.
voltage decreases.
Soldering
Limit soldering to 315¡C, 10 seconds duration, maximum.
Cleaning
Proper cleaning fluids should be selected, based on type of
contaminant to be removed. Alcohols or fluorinated solvents should be
suitable for general purpose use, subject to customer evaluation.
Measurand
P1:
Dry gases only.
P2:
Materials in contact with media are polyester, epoxy
adhesive and silicon bonded to borosilicate glass with an
electrostatic process.
V9965
11/99
1
V
4
2
0
3
Spannungserregung
Eccitazione di tensione
RS Stock No.
395-279, 395-285 and 395-291
When P2-P1 decreases, differential
loading

Resumen de contenidos para RS V9965

  • Página 1 Figures / Abbildung / Figura 21.5 21.5 Voltage excitation Spannungserregung 21.5 Eccitazione di tensione Excitaci—n de tensi—n RS Stock No. 21.5 395-279, 395-285 and 395-291 14.7 General 170PC pressure sensors are four-active-element piezoresistive bridges. When pressure is applied, a differential output voltage, proportional to that pressure, is produced.
  • Página 2 25 bis 50¡C Wiederholbarkeit und Hysterese ______________±0,25%FSO (typ.) RS Components shall not be liable for any liability or loss of any nature (howsoever caused and whether or not due to RS ComponentsÕ negligence) which may result Ansprechzeit ____________________________________1ms max.
  • Página 3 Puerto P1. Gases secos inicamente. General RS Components no ser‡ responsable de ningœn da–o o responsabilidad de cualquier naturaleza (cualquiera que fuese su causa y tanto si hubiese mediado negligencia de Los sensores de presi—n 170PC son puentes piezorresistivos de cuatro RS Componentscomo si no) que pudiese derivar del uso de cualquier informaci—n...
  • Página 4 2 e 4 (la tensione sul piedino 2, in relazione alla massa, aumenta mentre la tensione sul piedino 4 La RS Components non si assume alcuna responsabilitˆ in merito a perdite di diminuisce). Col diminuire della pressione, si riduce anche la tensione qualsiasi natura (di qualunque causa e indipendentemente dal fatto che siano dovute alla negligenza della RS Components), che possono risultare dallÕuso delle...