Fix the extractor to the wall in such a
way that it is not distorted in order to
avoid noise generation or problems
with the rotation of the impeller. Make
sure that the backdraught shutter
opens freely and has not being dam-
aged in transit. Introduce the mains ca-
ble through one of the cable point and
fi x it to the wall so that the fi xing screw
is above. Connect the electrical wiring
as set out below and then mount the
protection grille and tighten the screw.

ELECTRICAL CONNECTION

The FUTURE is an extractor designed
for a single phase supply, with volt-
age and frequency as indicated on the
rating plate of the unit. The units are
manufactured with double electrical
insulation (Class II) and therefore they
do not need an earth connection.
In addition to the switch shown in the in-
stallation drawing/diagram, there must
be an All Pole switch in the fi xed wiring
with a contact opening of min 3 mm.
The electrical cable must enter the
FUTURE through one of the cable
point. Once the cable has been intro-
duced proceed using the electrical
wiring diagram applicable to the se-
lected model.
FUTURE C, CZ
These models use the following dia-
grams:
Fig.3: Fan operating through the light
switch.
Fig.4: Fan operating through an inde-
pendent switch.
12
FUTURE T, CT, CTZ
These models are fi tted with an ad-
justable timer. The timer enables the
fan to continue running for the select-
ed period after the switch has been
turned off.
Fig.5: Fan operating through an inde-
pendent switch.
Fig.6: Fan operating through a light
switch.
The desired run-on time is selected
by means of an adjuster positioned
on the printed circuit board (fi g.7) and
accessible once the grille has been
removed:
• To reduce the run-on time, turn an-
ticlockwise (min. 1 minute)
• To increase the run-on time, turn
clockwise (max: 30 minutes).
FUTURE HT, CHT, CHTZ
Models provided with an electron-
ic humidistat which can be adjusted
from 60% to 90 % RH (relative hu-
midity) and with a timer, adjustable
between 2 and 20 minutes.
Specifi c recommendations
• If changing the settings of the fan
you have to handle the controls lo-
cated on the PCB. These adjusters
are fragile and must be handled
with care.
• For humidity measurement is cor-
rect we need the fan is installed
in an area where there is good air
circulation.
• Do not adjust the humidity outside
the room where the vent should be
installed.