RS V10037 Hoja De Instrucciones página 2

Idiomas disponibles

Idiomas disponibles

V10037
RS Stock
No. Supply
185-6090
12-48V
185-6107
12-48V
General
Counter and hour meter modules, with a 6-digit, 7-segment, 5mm high
LCD display. These single channel modules are designed for PCB
mounting.
The LCD of the hour meter module features a flashing hour-glass icon
which indicates hour meter activity. The icon flashes at a rate of 3
seconds on followed by 1 second off. During periods of inactivity, the
icon remains steady. A decimal point, before the last digit, separates
the hours from 1/10 hours.
Installation
The modules must be mechanically supported with all four pins
soldered to the board (see Figure 1). Electrical connections are as
shown in Figure 2.
Care should be taken during cleaning, after soldering the four
interconnection leads into the final assembly. No solvent, fluxes or
other chemicals must come in contact with the upper surface of the
PCB or the LCD assembly.
Do not use submersion cleaning, vapour degreasing or spray type in-
line cleaners.
Function
Counter module
The display is illuminated and the module powered up by applying
power between pins N (common) and P, e.g. by closing switch S2 (see
Figure 2). To commence or resume counting, V+ must be applied to pin
1 whilst the module is powered via pin P and N e.g. by closing switch
S3.
The reset facility is made available by connecting power between pins
N and R, e.g. by momentarily closing switch S4. Thus it can be
designed to be easily accessed using a push button, security activated
via a key switch or non-active by making no electrical connection,
according to the required application.
Hour Meter Module
The display is illuminated and the module powered up by applying power
between pins N (common) and P, e.g. by closing switch S2 (see Figure 2). To
commence or resume hour counting, power has to be applied between pins
N and I, e.g. by closing switch S3.
Power on hour meter applications may be easily catered for by permanently
linking P and I. The reset facility is made available by connecting power
between pins N and R. Thus it can be designed to be easily accessed using
a push button, security activated via a key switch or non-active, according to
the required application.
Technical specification
Supply voltage (counter) ____________________12-48V
Supply voltage (hour meter) ______12-48V
Operating current ____________________5.1mA max (12-48V
Operating frequency (DC only counter __________500Hz maximum
Pulse width (DC only counter) ____________________1ms minimum
Reset pulse (DC only counter) ________________300m/s minimum
Operating frequency (AC/DC hour meter) __________1 Hz maximum
Pulse width (AC/DC hour meter) ________________500ms minimum
Reset pulse (AC/DC hour meter) ______________300m/s minimum
Acuracy (AC/DC) hour meter) __________+ -48 seconds per 8 hours
2
RS Stock No.
Type
Counter
/ 20-60V
Hour Meter
nominal
/20-60V
nominal
9-60V
/15-75V
min./max.
3.5mA max (20-60V
Reset pulse __________________________________10s maximum
Accuracy (hour meter) ________________±30 seconds per 8 hours.
Temperature limits:
operating________________________________-40°C to +85°C
storage ________________________________-50°C to +90°C
Relative humidity ______________ 95% (non condensing at 38°C)
Shock resistance ____________________________ 50g at 9-13µs
Vibration resistance__________________________ 20g at 10-80Hz
Mounting details:
pin diameter ________________________________0.8 ±0.1mm
centres horizontal/vertical ____________________28mm/14mm
RS Components shall not be liable for any liability or loss of any nature (howsoever
caused and whether or not due to RS Components' negligence) which may result
from the use of any information provided in RS technical literature.
Best.-Nr.
Versorgungsspannung
185-6090
12-48 V
185-6107
12-48 V
Allgemeines
Sechsstellige Impuls- und Zeitzähler mit 7-Segment-LCD-Anzeige
(Zeichenhöhe 5mm). Einkanalmodelle für Tafelmontage.
Die LCD-Anzeige des Zeitzählers hat ein Sanduhrsymbol. Das Symbol
blinkt im Rhythmus 3 Sekunden ein/1 Sekunde aus, wenn der Zähler
arbeitet. Ist er nicht aktiv, leuchtet das Symbol stetig. Ein Punkt vor der
letzten Zeichenstelle trennt ganze Stunden von Zehntelstunden.
Montage
Die Zähler durch Anlöten der vier Stifte an der Platte befestigen (siehe
Bild 1) und wie in Bild 2 gezeigt verdrahten.
Beim Reinigen nach dem Anlöten der vier Anschlußdrähte am fertig
montierten Gerät mit Vorsicht vorgehen. Darauf achten, daß
Lösungsmittel, Lötmittel und andere Chemikalien nicht mit der
Oberfläche der Leiterplatte oder der LCD-Baugruppe in Berührung
kommen.
Keine Tauchreinigung, Dampfentfettung und Sprühreiniger verwenden.
Funktionsweise
Impulszähler
Sobald die Versorgungsspannung an Klemme N (Null) und P angelegt wird,
d. h. Schalter S2 schließt (siehe Bild 2), schaltet sich der Zähler ein und die
Anzeige leuchtet auf. Die Spannung V+ muß an Stift 1 gelegt werden,
während das Modul über die Stifte P und N eingeschaltet wird (z.B. durch
Schließen des Schalters S3).
Kurzfristiges Verbinden der Klemmen N und R (S4 schließt) bewirkt
Rücksetzen des Zählers. Die Rücksetzfunktion kann je nach Bedarf mit einem
Druckknopf zugänglich gemacht, durch einen Schlüsselschalter gesichert
oder ganz deaktiviert werden, indem man keine elektrische Verbindung
herstellt.
Zeitzähler
Sobald die Versorgungsspannung an Klemme N (Null) und P angelegt wird,
d. h. Schalter S2 schließt (siehe Bild 2), schaltet sich der Zähler ein und die
Anzeige leuchtet auf. Zum Einleiten oder Wiederaufnehmen des Zählbetriebs
muß durch kurzes Schließen von Schalter S3 eine Spannung an N und I
)
angelegt werden.
)
Einschalt-Zähleranwendungen lassen sich realisieren, indem man P und I
permanent miteinander verbindet.
Verbinden der Klemmen N und R bewirkt Rücksetzen des Zählers. Die
Rücksetzfunktion kann je nach Bedarf mit einem Druckknopf zugänglich
gemacht, durch einen Schlüsselschalter gesichert oder ganz deaktiviert
werden, indem man keine elektrische Verbindung herstellt.
RS Best-Nr.
Typ
Impulszähler
/ 20-60V
Zeitzähler
loading