OBJ_DOKU-6720646273-01.fm Page 16 Wednesday, April 13, 2011 6:26 PM
Cascading operation
2.2
Installation of Intelligent
Cascading Kit
Each appliance comes equipped with two
connectors inside for the installation of the
intelligent cascading kit. The connectors are
labeled 'cascading input' and 'cascading output'.
To access connectors, remove front cover per the
installation manual.
Although intelligent cascading will rotate the
primary appliance, it is essential to install the kit
starting with the appliance that is furthest from
the cold water main.
B Starting with the appliance furthest from the
cold water main, connect the male end of the
cascading cable to the connector inside
labeled 'cascading output'.
Fig. 2
Example of installation
1
Primary appliance
2
Secondary appliance
16
B Feed the cascading cable to the left from the
primary appliance through the hole at the
bottom of the adjacent secondary appliance.
B Connect to the 'cascading input' connector of
the secondary appliance (Fig. 2).
B Repeat this procedure for all the secondary
appliances.
B Complete the circuit by connecting a
cascading cable from the "cascading output'
connector on the last secondary appliance to
the "cascading input" connector on the
primary appliance.
Cascading cables may be connected
in series if one cable is not long
enough.
B The procedure is now complete.
3
Cascading Input
4
Cascading Output
6 720 646 273 (2011/03)