+GF+ SIGNET 2350 Temperature Sensor
3-2350.090-1
Safety Instructions
1. Do not remove from pressurized lines.
2. Do not exceed maximum temperature/pressure specifications.
3. Do not install/service without following mounting procedure.
4. Wear safety goggles and faceshield during installation/service.
5. Do not alter product construction.
6. Failure to follow safety instructions could result in severe personal injury.
The 3-2350 Temperature Sensors are pre-calibrated from -10 to 100°C (14 to 212°F) and are available in two versions.
Part No.
Cable Length
3-2350-1
15 ft.
3-2350-2
6 in.
1. Installation
All versions install in 3/4 in. NPT pipe fittings. Tighten sensor 1.5
turns past finger tight until the groove on the side of the sensor
aligns with the flow. An additional 3/4 in. pipe thread is provided
to attach a cable conduit (-1 version) or a +GF+ SIGNET integral
transmitter mounting kit (-2 version).
2. Wiring
Black
Silver
Red
3. Parts and Accessories
Part No.
5523-0222
A-9/99 E/G/F/S
Groove - must
be on side
pointing in
direction of
flow
Fin - must align
with flow
3-8350 Transmitter
Sensr V+
Sensr Gnd
Sensr In
Description
Sensor cable (per ft.)
4. Specifications
General
Temperature range:
-10 to 100°C (14 to 212°F)
Process connection:
3/4 in. NPT
±0.5°C
Accuracy:
±0.1°C
Repeatability:
Wetted materials:
PVDF/PN16
Cable type:
PVC jacketed, 2-conductor twisted pair
with shield (22 AWG)
Signal compatibility:
+GF+ SIGNET 8350 Temperature
Transmitter
Storage temperature:
-55°C to 100ºC (-67ºF to 212ºF)
Standards and Approvals
Manufactured under ISO 9001
CE
Dimensions
27 mm
(1.05 in.)
3/4 in.
NPT
105 mm
(4.15 in.)
40.1 mm
(1.59 in.)
2350-1
ENGLISH
197 mm
(7.75 in.)
2350
with integral kit and
transmitter (sold separately)
loading

Resumen de contenidos para GEORGE FISCHER SIGNET 2350

  • Página 1 +GF+ SIGNET 2350 Temperature Sensor ENGLISH 3-2350.090-1 A-9/99 E/G/F/S Safety Instructions 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Do not install/service without following mounting procedure. 4. Wear safety goggles and faceshield during installation/service.
  • Página 2 DEUTSCH +GF+ SIGNET 2350 Temperatursensor 3-2350.090(A-9/99) Sicherheitsvorschriften Nicht von unter Druck gesetzten Leitungen abnehmen. Die maximalen Temperatur-/Druckangaben nicht überschreiten. Bei der Installation/Wartung immer die Anleitungen zur Befestigung befolgen. Bei der Installation/Wartung Schutzbrille und Gesichtsmaske tragen. Die Produktbauweise nicht ändern. Eine Nichtbeachtung der Sicherheitsvorschriften kann schwere Verletzungen zur Folge haben.
  • Página 3 +GF+ SIGNET 2350 Capteurs de Température FRANCAIS 3-2350.090(A-9/99) Consignes de sécurité Ne pas séparer des conduites sous pression. Ne pas dépasser les spécifications maximales de température et de pression. Ne pas installer ni entretenir sans suivre la procédure de montage.
  • Página 4 ESPANOL Sensor de Temperatura +GF+ SIGNET 2350 3-2350.090(A-9/99) Instrucciones de seguridad 1. No retirar el dispositivo de líneas a presión. 2. No exceder los valores máximos especificados de temperatura y presión. 3. Seguir siempre el procedimiento de montaje para realizar trabajos de instalación o de servicio.