EPIX360™ Tru
TruElectrostatic
CONTENTS: After unpacking, inspect the components for any damage or missing
hardware pieces, etc. The following components are included with your purchase:
1)
TruElectrostatic
TM
2)
14.4v Rechargeable Battery (2)
3)
14.4v Battery Charger
1
2
Step 1: Installing and Removing the Battery
•
For best results, make sure the battery is fully charged.
•
To check charge, press down on the battery indicator light, the indicator will illuminate 3 green
bars when battery is fully charged.
•
To install, slide the battery pack into the EPIX360™ USB power source until the battery pack is
firmly seated.
•
To remove, grasp battery pack firmly, depress battery pack button down, and slide out from the
EPIX360™ USB power source.
Step 2: Liquid Tank Install and Removal
For the initial set up/test, remove the 8 oz. liquid tank from the spray system by
•
holding the tank cap cover and the tank, gently rocking it side to side while pulling
upwards (A).
To install the 8 oz. liquid tank into the spray system, align the tank nozzle to the
•
port on the body of the sprayer and gently press the tank until you feel or hear a
click as the Tank Lock and Back Clip will engage.
Step 3: Removing and Installing Tank Cap and Cover
With the tank removed from the system and holding it vertically, pull the tank cap cover
•
straight up (B). No twisting required (twisting will cause damage to the tank cap cover).
To remove the tank cap, gently twist counterclockwise.
•
To install the tank cap, gently twist clockwise, until cap no longer turns. Each cap has a
•
stopper that keeps you from overturning it.
To install the tank cap cover onto tank cap, simply line the cover up with the opening of
•
the tank cap.
Step 4: Pouring Solution into the Tank
Once the tank cap and cover are removed, simply pour the diluted or ready to use
•
solution into the already prepared tank and liner.
Note: A liner will last for 100 hours of use time or up to 3 months.
Step 5: Depress the Trigger Button to Begin Spraying
Once the system has been filled with solution, you can begin spraying. Depress the
•
trigger button, keeping it held down for entire spray time required.
Once trigger is released, the system will turn off.
•
The red indicator light at the back of system is the power indicator light. This turns on when you start spraying and will turn off
•
when the button is released. This light indicates the high voltage power supply is charging the liquid droplets.
133 Nursery Lane | Fort Worth, Texas 76114 | 888.534.7001 | Emist.com
©2021 EMist
®
is a registered trademark of SanoTech 360, LLC. All rights reserved. EMI-033-21-EPIX360 Multilingual QSG - 022621
Sprayer
4)
8 oz. Tank (includes the Tank, Tank
liner with Cap Washer, Tank Cap
with Filter, & Tank Cap Cover)
5)
8 oz. Tank Liner (4 extras included)
3
Sprayer Quick Start Guide
TM
4
5
Assembled
Unit
A
B
Tank Cap Cover
Tank Cap
C
Liner
Tank