INSTALLATION
STEP
7
Install
the
Door
Control
Locate door control within sight of door, at a
minimum height of 5 feet (1.52 m) where small
children cannot reach, away from moving parts of
door and door hardware. If installing into drywall, drill
5/32" holes and use the anchors provided. For
pro-wired installations (as in new home construction),
it may be mounted to a single gang box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of
bell wire and connect to the two screw terminals
on back of door control by color: white wire to
2 and white/red wire to the 1.
2. Remove white cover by gently prying at slot in top
of the cover with a small flat head screwdriver.
Fasten with 6ABx1-1/4" self-tapping screws
(drywall installation) or 6-32xl" machine screws
(into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of door control on screw head
and slide down to secure. Adjust screw for
snug fit.
• Drill and install top screw with care to avoid
cracking plastic housing. Do not overtighten.
• Insert top tabs and snap on cover.
3. (Standard
installation
only) Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Insert all wires through the opening on top of
motor unit above the terminal block on the right
side panel (Figure 3).
5. Strip 7/16" (11 mm) of insulation from each set of
wires. Insert door control wire into quick-connect
terminals by color: white wire to white, white/red
wire to red.
Separate white and white/black wires sufficiently to
connect to the opener quick-connect
terminals.
Twist like colored wires together. Insert wires
into quick-connect holes: white to white and
white/black to grey.
NOTE: When connecting multiple door controls to
the opener, twist same color wires together. Insert
wires into quick-connect
holes: white to white and
red/white to red.
6. Use tacks or staples to permanently attach
entrapment warning label to wall near door
control, and manual release/safety reverse test
label in a prominent location on inside of
garage door.
NOTE: DO NOT connect the power and operate
the opener at this time. The trolley will travel to
the full open position but will not return to the
close position until the sensor beam is connected
and properly aligned.
20
To prevent possible SERIOUSINJURYor DEATHfrom
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLYto 24 VOLTlow voltage wires.
To prevent possible SERIOUSINJURYor DEATHfrom a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet
(1.52 m), and away from all moving parts of door.
• NEVERpermit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLYwhen it can be seenclearly, is properly
adjusted,and there are no obstructions to door travel.
• ALWAYSkeep garage door in sight until completely
closed. NEVERpermit anyone to cross path of closing
garage door.
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white;
white/red to red.
HARDWARE
SHOWN ACTUAL
SIZE
'''>
Control Console (std installation)
Control Console (pro-wired)
Insulated
Staples
Drywall Anchors
Figure 1
REMOVE & REPLACE COVER
To Replace,
Insert Top
Tabs First
/ _
Figure 2
PRE-WIRED
INSTALLATION
24 Volt
2-Conductor
Bell Wire in
Gang Box
(BACK VIEW)
Top Mounting
Bell
I[_
Hole
Wire _T_J[.
Terminal
/I -' .oHF scrows
I1_'
I Bottom
Mounting
Hole
Quick-Connect
Terminals.
Lock
Light
To release wire push in
)oor Control
tab with screwdriver
tip
Connections
Strip wire 7/16" (11 mm)
7'18"
(11 rnm/
•
White Grey
Figure 3 Wiring to TerminaJ Block
Strip 7/16" (11 mm) of insulation from each wire. Insert
wires through opening on top of motor unit above
terminal block, then into quick-connect
terminals.