9
Maintenance
10
Technical data
Sensing range (with reflector PL80A)
Light spot diameter/distance
Supply voltage V
S
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1
16 VDC to 30 VDC, without load
2
10 VDC to 16 VDC, without load
3
Signal transit time with resistive load
4
With a light/dark ratio of 1:1.
5
A = U
-connections reverse polarity protected
V
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8020352.10DR | SICK
Subject to change without notice
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
MAINTENANCE
WLD16P
0.25 m ... 10 m
Ø 60 mm (5 m)
DC 10 ... 30 V
≤ 30 mA
1
< 50 mA
2
≤ 100 mA
≤ 500 μs
3
1000 Hz
4
IP66, IP67, IP69K
III
A, B, C, D
5
–40 °C ... +60 °C
9
11