4- MOUNTING AND WIRING MODULE
The BL-OL case must be installed indoor use only. It can be fixed against
a wall with the screws supplied with the product.
Cabling of the transformer to the power supply:
- The BL-OL case must be installed the nearest possible of the elec-
tric plug. The power plug must be accessible at all time in order to
unplug the device in case of emergency.
- Make sure that the power plug on which the transformer is plugged
in has a overcurrent and short-circuit protection breaker for 16 A
(20A for US).
Wiring of the 4 output lines:
- Each line must be protected by a circuit breaker which should be
identified and easily accessible.
- The 230 V (120 V in the U.S) cables which are used to power the 4
lines must have either a double insulation or a reinforced insulation.
- Cables used for wiring must be of type H05VV-F or H03VV-F and of
section 2 x 1,5 mm².
Maximum electric charge :
For a 230 V installation :
only 3500W on one single line.
For a 120 V installation :
to only 1700 W on one single ligne. Use only power supply provided
with product 120 V 0.75 A
*16 A max for resistive load
1,7A max for inductive load
Max operating temperature : 45°C.
4000 W (16 A*) total over all lines and up to
2000 W (16 A*) total over all lines and up
20