LOADING/CHANGING THE BATTERY
1.
Using a flathead screwdriver, rotate the battery
door lock to the unlocked position and
open the battery door.
2. Connect one 9V battery to the
connector block. Fit the battery
into the compartment.
(See Figure 1)
3. Close the battery door. Turn the
battery lock to the locked position.
SCANNING OBJECT TEMPERATURE
1.
Pull and hold the trigger for at least two seconds
and scan the surface temperature of an object. A
laser pointer is used for aiming on the area being
scanned.
NOTE: The object should be larger than the
spot being scanned. If not, readings will be
affected. See Figure 2 for necessary object size.
2. As you continue to hold the trigger, the
icon is displayed along with the
primary measurement (surface
temperature) and secondary
measurement (maximum, minimum,
average or differential temperature)
readings.
3. Release the trigger. HOLD is displayed
until the screen shuts off in about ten
seconds.
NOTE: A quick change in temperature (>10°F)
affects the meter's readings. Allow the meter to
reach ambient temperature before use (5 to 30
minutes, depending on temperature change).
DISTANCE TO SPOT – 10:1
—— Center of Spot
– – – Laser pointer (approx. 3/4" above center of spot)
Spot size at distance indicated
At 3' away,
spot is 3.6"
At 5' away,
in diameter
spot is 6"
in diameter
PAGE 3 OF 12
Figure 1
OPERATION
5 1 6
MAX
2
HOLD
5 1 6
MAX
2
Figure 2
At 1' away,
spot is 1½"
in diameter
ASSEMBLY
SELECTING CELSIUS OR FAHRENHEIT
To set the temperature scale, pull the trigger, then press
the SET button three times. Press the buttons above the
up and down arrows to toggle between "C" and "F." Wait
five seconds for the setting to save and exit.
SETTING THE LASER LOCK
To turn the laser on and off, pull the trigger, then press
the SET button four times. Press the buttons above the up
and down arrows to toggle between ON and OFF. Wait
five seconds for the setting to save and exit.
SETTING THE TRIGGER LOCK
1.
To turn the trigger lock on and off, pull the trigger, then
press the SET button five times. Press the buttons above
the up and down arrows to toggle between ON and
OFF. Wait five seconds for the setting to save and exit.
TEMPERATURE ALARM
1.
Press the ALARM button to turn on the
alarm function.
2. The bell icon is displayed. If the
temperature reading is outside the preset
0
range, the temperature reading will flash
8 1
3
and an alarm will sound.
SETTING PRESET RANGE FOR THE ALARM
0
1.
To set the alarm range, pull and hold the
trigger, then press the SET button. Repeat to
8 1
3
toggle between LO and HI settings.
2. Press the up or down arrow soft keys to
toggle between temperatures. Wait five
seconds for the ranges to save and exit.
LOW BATTERY
When the low battery icon is displayed, change the battery.
WARNING! Always remove battery before
changing or removing accessories. Only use
accessories specifically recommended for this
tool. Others may be hazardous.
Mode
Description
Displays maximum temperature measured during a
MAX
continuous reading.
Displays minimum temperature measured during a
MIN
continuous reading.
Displays average temperature of last 20 measurements
AVG
during a continuous reading.
Displays the difference between MAX and MIN during a
DIF
continuous reading.