Usage instructions for AquaLight 20/35
GB
Libel AquaLight Underwater Spotlight
Voltage
Bulb
Transformer
Cable length
Power consumption
Max. immersion depth
Guarantee
Includes:
The AquaLight 20/35 spotlight must only be used as an underwater spotlight. The spotlight
operates with low voltage, and comes complete with the required transformer.
Installation
In order to attach the spotlight to a fitting such as the ascending nozzle pipe of a garden
pond pump, a spotlight clamp is included. The universal mounting foot is used for
attachment to other objects. The spotlight can also be installed on a flat, smooth surface
using the suction pads. Please note that the socket for the transformer should be at a
distance of at least 3.5 m from the pond.
Changing the bulb
1. Remove the plug from the socket
2. Remove any remaining water
3. Unscrew the lamp ring
4. Carefully remove the glass lens of the spotlight
5. Replace the bulb
6. Dry the lens and the lamp ring thoroughly and refit them, taking care to ensure the
correct position of the sealing ring!
Installing a coloured lens
To install a coloured lens, unscrew the lamp ring and replace the coloured lens, taking
care to ensure the correct position of the sealing ring. Then reassemble in the reverse
order, tightening the ring firmly by hand.
Cleaning
Proceed as for changing the bulb. Use only clean water and a soft brush. Ensure that no
moisture gets into the spotlight!
Repair
In the event of damage to the cable, housing or transformer, the unit cannot be repaired,
and must be completely replaced.
3
230 V AC / 50 Hz
Halogen, QR-CB 51, 20/35 W GU 5.3
230 V AC / 12 V AC - 20 VA (AquaLight 20) / 35 VA (AquaLight 35)
5 m
20 W (AquaLight 20) / 35 W (AquaLight 35)
1 m
2 years
4 coloured lenses, mounting foot, transformer