Service - Sears 390.305001 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

General
Risk of electric shock. When servicing
pump always disconnect power to electrical outlet
and remove pump electric cord from outlet.
1. If pump does not operate:
a. Check for loose plug at electric outlet.
b. Check for blown fuses or tripped circuit breakers at
fuse box/circuit breaker box.
c. Be sure nothing interferes with action of automatic
float switch.
d. If a, b, and c above check OK, plug in a light that you
know works. If it lights, take your pump to Sears for
service. If it doesn't light, the electrical circuit is faulty;
consult a licensed electrician.
2. Pump starts, but blows fuses/trips circuit breakers:
After disconnecting power to pump, remove the screen
and shield from the bottom of the pump and make sure
that the impeller turns freely. Remove any debris ob-
structing impeller. If pump still does not operate cor-
rectly, return it to your nearest Sears Service Department
for repairs.
3. Pump runs, but does not empty sump:
a. Clean pump intake screen.
b. Water may be entering sump faster than the pump can
discharge it.
c. Be sure vertical distance from pump discharge outlet
to discharge pipe outlet does not exceed maximum
vertical pumping distance shown in "Specifications,"
below.
d. Be sure discharge pipe is not plugged or frozen.
Stock
Maximum
Number
HP
Amps
3050
1/2
7.6
SERVICE / SPECIFICATIONS
SPECIFICATIONS
Dimensions in inches (mm)
Length
Width
9" (229)
6-1/2" (165) 11-1/2" (292)
TEATHERED SWITCH REPLACEMENT
NOTICE: Teathered float must be able to swing through its
complete arc without interference from sidewall of sump,
plumbing or any other object.
1. Remove pump power cord from switch plug.
2. Remove tether clamp screw and slide cord from clamp.
3. Insert new cord in tether clamp. Put the clamp at the
same distance from the float that it was on the old switch.
4. Tighten tether clamp screw.
5. Check sump pump operation by filling sump with water
and observing operation through one complete cycle.
Failure to check installation with water
in sump can lead to improper operation, premature
pump failure and flooding.
GPM (L/min.) at Vertical Pumping Distance in Feet (M)
Height
5' (1.6)
10' (3)
61 (231)
56 (212)
6
15' (4.6)
20' (6.1)
25' (7.6)
50 (189)
43 (163)
34 (129)
Tabla de contenido
loading

Este manual también es adecuado para:

390.305002

Tabla de contenido